USER MANUAL
CLS-1602-006
MINI CENTRIFUGE, DIGITAL, TIMER,
ADJUSTABLE RPM, CAPP RONDO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Capp Rondo CLS-1602-006 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chemglass Capp Rondo CLS-1602-006

  • Page 1 USER MANUAL CLS-1602-006 MINI CENTRIFUGE, DIGITAL, TIMER, ADJUSTABLE RPM, CAPP RONDO...
  • Page 2: Table Of Contents

    INTRODUCTION INTENDED USE FEATURES TECHNICAL SPECIFICATIONS STANDARD ACCESSORIES SAFETY PRECAUTIONS INSTALLATION STANDARD PART LISTING ROTOR BALANCING INTERCHANGEABLE ROTOR CHANGING THE ROTOR OPENING CENTRIFUGE LID OPERATION CARE AND MAINTENANCE WARRANTY STATEMENT PRODUCT DISPOSAL...
  • Page 3: Introduction

    1. INTRODUCTION This Micro offers Centrifuge versatility, simplicity, safety, ease usage This has been after and its single package. product designed studying centrifuges usage in numerous scenarios of the lab environment. This Micro suitable for cell centrifuge specially microfiltration, separations, tube down Please read this...
  • Page 4: Technical Specifications

    4. TECHNICAL SPECIFICATIONS Motor Type Brushless DC Motor 8 x 1.5 /2.0 ml Tube Rotor & 2 Place PCR Strip Rotor Rotor Capacity 2000 6000 RPM Speed Setting 2000 x g (MAX RCF) Speed Accuracy ± 25 RPM Time O To 25 Mins & Infinite Size (w X D X H) 162 x 157 x 116 mm 1.1 Kg...
  • Page 5: Installation

    • Make sure to always use only specified micro centrifuge tubes made from plastic and designed to withstand centrifugal forces of at least 2000 g. • Do not operate the centrifuge without the rotor being properly attached to the shaft. Re-check by trying to pull it up manually, especially after the rotor has been changed or re-assembled.
  • Page 6: Standard Part Listing

    RCF CHART ROUND ROTOR PCR STRIP 0.2 ml 0.5 ml 1.5ml 0.2 ml 1000 35.5 2000 3000 4000 4500 1053 1098 1050 1177 1300 1356 1297 5000 6000 1276 1695 1872 1952 1868 8. STANDARD PARTS LISTING PROTECTIVE LID ON/OFF SWITCH--+-+-1..n ( eJ-11-t--+- POWER SOCKET NON SLIP RUBBER BASE...
  • Page 7: Interchangeable Rotor

    If the tubes are not loaded symmetrically then the imbalance detector will cut off the running centrifuge for device & user safety. The following are the incorrect methods of loading tubes in the centrifuge the rotor. V � U 0.2 ML 0.4 ML 0.5 ML 1.5 ML/ 2.0 ML...
  • Page 8: Opening Centrifuge Lid

    screw again. Turn clockwise to tighten the screw which is located under the bottom of rotor. Please check that the rotor is tight enough to avoid any accidents. Tightening the screw will be in clockwise direction and the loosening will be in counter Note: clockwise direction ----- Sticker Mark...
  • Page 9: Operation

    -.,1:::11:: .- ..:.=-=:�ii\i-=:�- Lid Release Button Correct Method To open the centrifuge lid, press the "Lid Release" button down. Lid Release Correct Method Button 13. OPERATION To operate this Micro Centrifuge, the below steps should be followed: Connect the power adaptor & Switch 'On' from the rear side so that the display will show you the fix RPM readings.
  • Page 10 TIME CONTROL, SPEED CONTROL AND DISPLAY The unit is equipped with a 0-25 minutes timer. By operating the timer knob one can set the desired time cycle. The time increments/ decrements will be in minutes and will show on display and indicator. Time indicator display Infinite time display The timer can be set from 00 to 25 minutes.
  • Page 11 ,,-. . - , - , . )( 1 0 0 RPM x1 0 0 RPM OJeMi n f Min Imbalance activated display Imbalance de-activated display If the display sh ows"En " that If the display sh ows"dS"it means t h e imbal ance means t h e imbal ance detection is activated detection is de-activated...
  • Page 12: Care And Maintenance

    User action: the lid of the unbalanced load various methods Open centrifuge, correct described in the the rotor of this manual. Then close the lid and 'reset balancing part is done 'Off' and 'On' the centrifuge'. Resetting by switching again switching located the rear side of the centrifuge by using the On/Off switch...
  • Page 13: Product Disposal

    for any intended purpose and that there are no other remedies or warranties, expressed or implied, which extend beyond the description on the face of the agreement. This warranty is only applicable to the original purchaser. Products received without proper authorization will not be processed for warranty or service.
  • Page 14 3800 North Mill Road, Vineland, NJ 08360 Phone: US & Canada 1-800-843-1794 • International 1-856-696-0014 Fax: US & Canada 1-800-922-4361 • International 1-856-696-9102 www.cglifesciences.com • tech@cglifesciences.com...