MASH DEPLOYMENT GUIDE – Yodock
The Yodock
®
2001MB ("2001MB") has been tested pursuant to the Manual for Assessing
Safety Hardware 16 ("MASH 16") Test Level 2 ("TL-2") specifications.
The 2001MB is a plastic Longitudinal Channelizing Device ("LCD") used for traffic and
pedestrian channelization, road closure, and perimeter security for vertical construction.
When assembled as an LCD, the 2001M
16 TL-2 LCD on the National Highway System ("NHS").
Features
1. Interlocking Coupler
2. Light Box Recess
3. Fill Cap & Port
4. Drain Hole & Plug
5. Forklift Ports
Specifications
6' length
18" width
32" height
Empty Weight: 85 lbs.
Full Weight: 900 lbs.
Capacity: 100 gallons
LCD
Ballast Capacity: 60 gal.
Ballasted Weight: 575 lbs.
Fence Assembly
Ballast Capacity: 100 gal.
Ballasted Weight: 900 lbs.
Recommended Tools
Drain Wrench
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE OR CAUSE SERIOUS INJURY TO PEDESTRIANS AND
VEHICLE OCCUPANTS.
TrinityHighway.com
is eligible for Federal-Aid reimbursement as a MASH
1
© 2021 Trinity Highway Products, LLC
1
®
2001MB
3
2
5
PERIMETER SECURITY WITH
FENCE PANEL FILL LEVEL
(100 gal.)
LCD
FILL LEVEL
(60 gal.)
Part No. 627705
Created July 2021
4

Advertisement

loading
Need help?

Need help?

Do you have a question about the Yodock 2001MB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trinity Highway Yodock 2001MB

  • Page 1 FENCE PANEL FILL LEVEL (100 gal.) FILL LEVEL (60 gal.) FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE OR CAUSE SERIOUS INJURY TO PEDESTRIANS AND VEHICLE OCCUPANTS. Part No. 627705 © 2021 Trinity Highway Products, LLC TrinityHighway.com Created July 2021...
  • Page 2 Longitudinal Channelizing Device (LCD) Deployment 1. Determine the deployment location of 2001MB and follow the instructions of the highway authority or project manager (if available). 2. Deploy the barricades, empty, in line with each other and join each unit to the next using an Interlocking Coupler.
  • Page 3 2001MB Removal 1. Loosen Fill Caps to facilitate water removal. 2. Remove the Drain Plug at the base of the barricade and drain water completely. 3. After the barricade is empty, attach Drain Plug, Fill Cap, and remove Interlocking Coupler. 4.
  • Page 4 Perimeter Security with Fence Panel Deployment (Not MASH Tested) Warning: The 2001MB with Fence Panels should only be deployed on level ground. 1. Position each 2001MB in line with the next using Interlocking Couplers. 2. If a connection is required to make a corner, use the 2001MB Corner Connector and join it to the adjacent 2001MB Barricade run using an Interlocking Coupler (p.
  • Page 5 Perimeter Security with Fence Panel Removal 1. Remove privacy, wind or debris screens (if attached). 2. Remove Fence Panel Clamps. 3. With the assistance of an additional person or persons (as needed), lift the Fence Panel out of the barricade and place on the ground. Remove and retain each Rubber Grommet. 4.