Download Print this page

Rechner Sensors KXA-5-1 Series Adjustment Instructions Manual page 13

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Technical data KXA-5-4...FB... (Master/Slave) with sensor break control
Technical data
Output function
Type NPN
Art.-No.
Type PNP
Art.-No.
Operating voltage (U
B
Output current max. (I
Permitted residual ripple max.
No-load current (I
)
o
Permitted ambient temperature
LED - display
Protective circuit
Degree of protection IEC 60529
Connection
Housing material
Wire break control
Output wire break
Dimensions: See dimension No. 2, page 33.
Connection diagram:
KXA-5-4-N-S-4FB-Ö-CC-MINI
KXA-5-4-P-S-4FB-Ö-CC-MINI
)
)
e
4 x Normally open
XA 0033
XA 0024
18...36 V DC
400 mA each output
40 %
130 mA
-25...+55 °C
Green / yellow
Built-in
IP 54
Screw terminals and
triax socket
ABS
1 x each channel
4 x Normally closed
BE = Connection to the machine or plant
potential
MS = Connection to the slave (optional)
A1, A5 Output and wire break signal channel 1
A2, A6 Output and wire break signal channel 2
A3, A7 Output and wire break signal channel 3
A4, A8 Output and wire break signal channel 4
4 x Normally open
KXA-5-4-N-S-4FB-Ö-CC
XA 0034
KXA-5-4-P-S-4FB-Ö-CC
XA 0020
18...36 V DC
400 mA each output
40 %
130 mA
-25...+55 °C
Green / yellow
Built-in
IP 54
Screw terminals and
triax socket
ABS
1 x each channel
4 x Normally closed
13

Advertisement