INSTRUCTIONS - INTERFIT
240 Volt Motor Controller for
4 Core Projection Screens, AV Lifters and Motorised Blinds
Motor Wiring
Pin 1 - Brown Screen Down
Pin 2 - Black Screen Up
M
Pin 3 - Yellow/Green Earth
Pin 4 - Blue Neutral
1
2
Motor Output
IR Receiver
Input
Infra Red
Receiver
o
o
Vertical Up Lift
240 V
Input
IEC
3
4
Socket
Connect Network
Contact Close
Out
In
Input
RJ12 Connector
6 Core wired
straight through
240 VOLT MAINS CONNECTIONS
•
The iConnect motor controller is supplied with a 240 V IEC power lead for connection to a
standard GPO.
•
The 240 V output to the 4 core motor is via the supplied WAGO connector.
PIN WIRING CONFIGURATION
•
Pin 1 Brown (Motor Down)
•
Pin 2 Black (Motor Up)
•
Pin 3 Green/Yellow (Earth)
•
Pin 4 Blue (Neutral)
Next Connect Module
Maximum 9 Modules
POWER ON INDICATOR (NEXT TO IR INPUT)
•
When LED is Green, indicates mains 240V
Connect Network
present and iConnect module is on.
•
When LED is Red, indicates that iConnect
In
module is in program mode.
Out
Mains
In
FOR INFRA RED OPERATION YOU WILL REQUIRE
(SUPPLIED SEPARATELY)
•
Screen Technics 2 Channel infra red
Out
transmitter (Product Code 6500101)
•
Screen Technics Connect infra red sensor
(Product Code 6500102 Length 300mm) or
(Product Code 6500103 Length 2000mm).
•
Infra red receiver is connected to the IR
receiver input on iConnect module.
•
Factory standard infra red operation is infra
red channel one (1).
•
For individual infra red channel control (up to
9 Infra Red Channels can be programmed via
the 6 button infra red transmitter if required.
(Contact Screen Technics for details)
•
•
•
•
IR Receiver
•
•
•
•
•
•
•
•
Infra Red
Receiver
Infra Red
Receiver
•
•
•
•
•
•
•
3
Input
IR Receiver
Input
IR Receiver
Input
IR Receiver
Input
Continued Over.../