INSTRUCTIONS - INTERFIT

240 Volt Motor Controller for

4 Core Projection Screens, AV Lifters and Motorised Blinds
Motor Wiring
Pin 1 - Brown Screen Down
Pin 2 - Black Screen Up
M
Pin 3 - Yellow/Green Earth
Pin 4 - Blue Neutral
1
2
Motor Output
IR Receiver
Input
Infra Red
Receiver





o 
o 
Vertical Up Lift
240 V
Input
IEC
3
4
Socket
Connect Network
Contact Close
Out
In
Input

RJ12 Connector
6 Core wired
straight through



240 VOLT MAINS CONNECTIONS
The iConnect motor controller is supplied with a 240 V IEC power lead for connection to a
standard GPO.
The 240 V output to the 4 core motor is via the supplied WAGO connector.
PIN WIRING CONFIGURATION
Pin 1 Brown (Motor Down)
Pin 2 Black (Motor Up)
Pin 3 Green/Yellow (Earth)
Pin 4 Blue (Neutral)
Next Connect Module
Maximum 9 Modules
POWER ON INDICATOR (NEXT TO IR INPUT)
When LED is Green, indicates mains 240V
Connect Network
present and iConnect module is on.
When LED is Red, indicates that iConnect
In
module is in program mode.
Out
Mains
In
FOR INFRA RED OPERATION YOU WILL REQUIRE
(SUPPLIED SEPARATELY)
Screen Technics 2 Channel infra red
Out
transmitter (Product Code 6500101)
Screen Technics Connect infra red sensor
(Product Code 6500102 Length 300mm) or
(Product Code 6500103 Length 2000mm).
Infra red receiver is connected to the IR
receiver input on iConnect module.
Factory standard infra red operation is infra
red channel one (1).
For individual infra red channel control (up to
9 Infra Red Channels can be programmed via
the 6 button infra red transmitter if required.
(Contact Screen Technics for details)

• 

• 
• 
• 
IR Receiver

• 

• 
• 

• 
• 

• 
• 
• 
Infra Red
Receiver
Infra Red
Receiver












3
Input

IR Receiver
Input

IR Receiver
Input

IR Receiver
Input
