INSTRUCTIONS - INTERFIT


DOOR OPENING MECHANISM - STANDARD FITTING
          
The InterFit Vertical Up Lift comes with an integrated door opening

solution which works as follows:

            
STEP 1.
Bolted to the LH side of the lifter up-right is a full height door guide
              
with a nylon runner wheel mounted at the top, which pushes open the

door on the upward travel.
           
STEP 2.
You should mount the panel unit so that it is level with the top of

this nylon runner wheel - you may need to trim the door guide arm to

suit, making sure it still goes all the way to the bottom of the unit, so
           
the door does not get trapped under it when in the up position. You can
           
slide the door guide arm up or down by loosening the channel bolts

accordingly.
            
STEP 3.
The unit is supplied with 2 off (White & Black) nylon wear pads that are designed to be fitted

and to protect the underside of your opening door and glide along the edge of the door guide. Two

colours supplied for door colour matching purposes.

               
STEP 4.
It is recommended that the hinge or pivot point for the door be 50mm back from the outer
            
edge of the door guide arm, as this will stop the door from over tilting and falling back away from
the mechanism.

STEP 5.
If you don't have enough room for the recommended 50mm pivot point then you will require
a spring tension system to pull the door against the lifting unit and stop the door overbalancing - a
solution is available from Screen Technics, please contact during office hours to enquire.
             
Keep in mind the door weight / panel weight combination must be within published specifications for
             
maximum unit capacity (marble or granite tops may be an issue). See design sheet for details.


FIXED DOOR MOUNTING PLATE - OPTIONAL EXTRA FITTING
       

Enables a cut piece of cabinet or bench top (within
specified weight restrictions) to be flush mounted to the

top of the Lifting unit
      
Enables a cut piece of cabinet or bench top (within

specified weight restrictions) to be flush mounted to
     
the top of the Lifting unit.
         
T Section mounting plate is adjustable for height
utilising the side locking Allen Key bolts.
      
Ensure that no obstructions exist with this style of

door fitting as it will close flush with exiting cabinet
      
and possibly damage any items that get in the way.
     
We recommend a non latching switch that

necessitates someone to keep pushing the control
switch until the unit is fully closed as a safety measure.


Vertical Up Lift
Close up of mechanical fall arrester - safety first!

GENERAL ADVICE
The up and down stop positions are set using the limit adjustment switches and are set at the
factory to allow maximum travel distance - due care must be taken if adjusting these limit

switches as any damage caused to the unit will void any warranty.

The unit requires no maintenance throughout it' s life, although an inspection should be carried

out approximately every l8months.

Please ensure any cables are safely away from any moving parts.

When reversing direction of the travel in this unit a minimum delay of half a second is required
to be programmed in to prevent instant reversals.


