REMEDY
It is quite difficult to determine whether this trouble is caused by the refrigerating oil left in the
evaporator tubing ,because this kind of phenomenon and other several trouble are tends to be
confused .Generally speaking ,you can make a judgment based on the frost formed on the
evaporator .If the frost does not cover the evaporator , and moreover ,it is loosely formed ,you can
make a judgment that the deterioration of refrigerating effect is due to the accumulation of refrigerating
oil left in the evaporator tubing in case no other troubles have been found . To clear off refrigerating oil
left in the evaporator ,dismantle the evaporator ,purge it thoroughly and then dry it .In case it is difficult
to dismantle it ,charge refrigerant from the evaporator inlet to wash it several times ,then purge and dry
it with nitrogen .
7) Flowing obstructed in refrigerating system
ANALYSIS OF TROUBLE
Because the refrigerating system was originally not purged thoroughly ,some of the filter screen
meshes have been clogged by dirt accumulated in the filter after using it for a certain time of
period ,thus resulting in a decrease in flow rate ,and hence a poorer refrigerating effect .
The abnormal phenomena caused by this kind of slight clogging in the system are as follows: the gas
discharge pressure is lower ,the temperature of discharged gas drops down ,the position clogged has
a temperature lower than that in normal conditions ,and for a severe clogging ,even dew condensation
as frosting may appear .
REMEDY
Purge the tubing ,and after replacing the dry filter with a new one or clearing it thoroughly ,recharge the
system with refrigerant and seal the charging port .
B. No Refrigerating
The phenomenon that the compressor runs normally ,but no frost (or only a little frost ) appears on the
evaporator ,and the refrigerator temperature does not drop down is called "no refrigerating". There are
many causes for this trouble and it is relatively complicated , too . In servicing ,special attention to
finding direct causes for this phenomenon .Three main potential causes for this trouble are analyzed
below :
1) All refrigerant in the system has leaked out
ANALYSIS OF TROUBLE
Leak points in the refrigerating system have not been found and repaired timely ,thus resulting in the
total escape of refrigerant .There are two kinds of leakage :I) slow leakage for instance ,when we want
to use a refrigerator that has been put out of quite a long time ,we find the leakage of refrigerant ,or in
the course of its operation ,we have found that the refrigerator is gradually becoming not so cold and
finally no refrigerating cab be achieved ; ii) fast leakage in that case ,all the refrigerant will escape
swiftly due to abrupt rupture of system tubing .
Symptoms of total leakage of refrigerant are mainly as follows : the compressor can be started easily
(if there is no damage to the compressor parts) and its operating current becomes low ,its gas suction
pressure is high and discharge pressure is lower ,the gas discharge tube feels rather cold ,no sound of
gas eruption from the liquid in the evaporator can be heard ,and no will gush out of the process tube if
you cut it open after shutdown .
REMEDY
Check the whole machine , particularly those locations which are liable to leak .After leak points have