Troubleshooting - Desa H18NB Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
When control knob is pressed
in and turned to PILOT, there
is not spark at ODS/pilot
When control knob is pressed
in and turned to PILOT, there
is spark at ODS/pilot but no
ignition
124465-01A

TROUbLESHOOTING

POSSIBLE CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or
wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned
wrong
1. Gas supply turned off or
equipment shutoff valve
closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when in-
stalled
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is
not correct
www.desatech.com
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
3. Replace valve
4. Replace valve
5. Replace pilot
6. Reposition ignitor electrode
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while
in PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP
gas company
6. Clean ODS/pilot (see Clean-
ing and Maintenance, page
19) or replace ODS/pilot
assembly
7. Replace gas regulator
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Н18рвH24nbH24pb

Table of Contents