Acknowledging faults
1
1. If the fault pop-up is accompagnied with a buzzer
press the
SELECTION WHEEL (X) on the
control panel once to silent the buzzer.
2. Read the fault pop-up it will alternate between
"source of fault/cause of fault" and "actions to
take."
1
CAUTION! If a DANGER or WARNING pop-up
with request "Stop engine" appears, it is rec-
ommended to stop the engine at once.
3. Acknowledge the fault by pressing the
SELECTION WHEEL (X) on the control panel a
second time. The pop-up will disappear.
4. Take the recommended actions. Please refer to
the "Fault handling" chapter, section "Fault regis-
ter" in the operator's manual.
NOTE! All faults are erased when the starter key is
turned to the stop position (S).
NOTE! Unattended faults will result in new fault pop-
ups every time the system is powered up or when the
engines are started.
Acknowledging faults on Docking Station
A flashing LED above the
ALARM ACKNOWL-
EDGE BUTTON indicates which engine (1/2/3) is
faulty. A more serious fault is also indicated with a
buzzer.
1. Acknowledge the alarm with the
ALARM
ACKNOWLEDGE BUTTON. The LED above the
button stops flashing and lights continuosly. The
buzzer is silenced.
2. Activate a station that is equipped with displays in
order to read and acknowledge the fault pop-up.
3. Take the recommended actions. Please refer to
the "Fault handling" chapter, section "Fault regis-
ter" in the operator's manual.
2
3
Retrieving faults
Faults set in the system during a trip can be viewed
in the FAULTS MENU. Follow the instructions be-
low:
1. Select which engine (display 1/2/3) to check
for faults. Use the
BUTTON.
2
3
2. Press the
reach the FAULT view in the FAULTS AND
SETTINGS MENU (B).
NOTE! A POINTING HAND-symbol in a view
indicates a SUB-MENU. if there is no fault
(FAULTS 0) in the FAULTS veiw there is no
SUB-MENU for FAULTS.
3. Press the
you will enter the SUB-MENU for FAULTS (C).
4. Turn the
view the faults set in the system.
NOTE! When in a menu other than the MONITOR-
ING MENU (A), push the BACK BUTTON to return
X 1
2
3
to previous menu. Push repeatedly and you will re-
turn to the MONITORING MENU (A).
1
3
2
DISPLAY SELECTION
BACK BUTTON and you will
C
SELECTION WHEEL (X) and
SELECTION WHEEL (A) and
A
Volvo Penta IPS
triple installation
POCKET GUIDE
Activating station
Monitoring EVC information
Acknowledging faults
Retrieving faults
B
NOTE! This pocket guide contains short
version of some of the panel and dis-
play instructions found in the operator's
manual for Volvo Penta IPS triple instal-
lation. This pocket guide is not meant to
be a substitute for the instructions in the
operator's manual, it is only meant to be
a memory aid. Read the operator's man-
ual thoroughly before using this pocket
guide.
AB Volvo Penta
SE-405 08 Göteborg, Sweden

Advertisement

loading
Need help?

Need help?

Do you have a question about the SE-405 and is the answer not in the manual?

Questions and answers

Summary of Contents for Volvo Penta SE-405

  • Page 1 Acknowledging faults on Docking Station play instructions found in the operator’s manual for Volvo Penta IPS triple instal- A flashing LED above the ALARM ACKNOWL- lation. This pocket guide is not meant to EDGE BUTTON indicates which engine (1/2/3) is be a substitute for the instructions in the faulty. A more serious fault is also indicated with a...
  • Page 2 Activating station Monitoring EVC information Each engine (1, 2 and 3) has its own display. ACTIVATION BUTTON NOTE! Each EVC system display have three win- Push this button on the control panel to activate a dows. The two windows beside each other in the station. upper section of the display (shows engine rpm and NOTE! The control levers on all stations must be in coolant temp) are fixed and cannot be controlled by neutral position the control panel. LED indication above the button: Red The displays always start up in the MONITORING Off: The station is not active. MENU (A). The following buttons are used when Lit: The station is active. monitoring EVC information: Flashes: The station can not be activated due to the control levers not being in neutral on all stations or DISPLAY SELECTION BUTTON that another station is active and locked. When you want to shift information type in a display you need to select that display using this button. Locking/unlocking station Lock an active station by pushing the LED indication above the button: Red/Yellow/ ACTIVATION BUTTON.