INSTALLING THE SCSI BOARD (VS4S-1) / / / /
SCSI ボード(
ボード(
ボード(
ボード(VS4S-1)の取り付け方法
)の取り付け方法
)の取り付け方法
)の取り付け方法
♦ ♦ ♦ ♦ Procedure:
1. Turn off the power for the MC-80 and any connected
devices, and disconnect any cables connected to the MC-
80.
2. Turn the MC-80 over, and remove the bottom cover,
(See fig.1 to remove 12 screws.)
fig.1 Bottom Cover View
Remove 12 screws circling in this figure./
3. Remove the EXP COVER on the rear panel.
(See fig.2 to remove 2 screws.)
fig.2 Rear Panel View
Remove 2 screws circling in this figure./
4. Insert a supplied fuji-card into the SCSI Board's
connector(CN1).
Be sure both contacts are facing each other.
5. Insert the SCSI Board, with its parts surface facing
upwards, into the opening of EXP slot.
6. Secure the SCSI Board with 2 screws. Insert the other end
of a fuji-card into the MC-80 JACK BOARD's
connector(CN108).
(See fig.3 in detail.)
7. Attach a supplied core on the wiring inserted in the MC-80
JACK BOARD's connector(CN106).
(See fig.3 in detail.)
24
◆手順
◆手順
◆手順
◆手順
1. MC-80 と接続している機器の電源を切り、MC-80 に接続
されているすべてのケーブルを外します。
2. MC-80 を裏返し、ボトムカバーを外します。
(外すネジは fig.1 を参照してください。 )
3. 続けてリアパネルの EXP カバーを外します。
( 外すネジは fig.2 を参照してください。 )
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS
SUBJECT TO THE FOLLOWI NG TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
CAUTION
ATTENTION:
RISQUE DE CHOC
ELECTRIQUE NE PAS
OUVRIR
4. SCSI ボードの CN1 に SCSI ボード付属のフジカードを挿
します。
フジカードの向きを間違えないように注意してください。
5. 先ほど開けた EXP スロットへ、部品面を上にした VS4S-1
ボードを挿します。
6. SCSI ボードのパネルをネジで止めた後、フジカードのも
う片方をジャックボード CN108 に挿します。
( 詳細は fig.3 を参照してください。 )
7. ジャックボードの CN106 から出ているワイヤリングに
SCSI ボードに付属のコアを付けます。
( 詳細は fig.3 を参照してください。 )
CN106
MC-80 JACK BOARD
CN105
CN103
CN111
supplied core
fig.3 How to install the supplied core and fuji-card
8. Re-attach the bottom cover.
9. Checking operation.
a. Prepare an external ZIP drive,a 25pin SCSI cable and a
formatted ZIP disk.
b. Connect the external ZIP drive and SCSI Board
connector with a SCSI cable.
c. Connect the AC cord to the MC-80.
d. Turn on the power for the external ZIP drive.
e. Turn on the MC-80 power while holding down [CHAIN
PLAY],[REC] and [ARPEGGIATOR] at the same time.
f. Insert the ZIP disk into the external ZIP drive after
entering the test mode.
g. After pressing [F6(next)], MC-80 automatically executes
the device checking.
h. The system properly operates, when the SCSI icon is
NOT displayed.
Make sure of the following, when the SCSI icon is
displayed.
SCSI
-Check that the supplied fuji-card is inserted
properly.
Dev Err!
-Check that the external ZIP drive is connected
properly.
No Disk!
-Check that the formatted ZIP disk is inserted into
the external ZIP drive.
10.Executing the operation of shutdown.
a. While holding down the [SHIFT] button, press the [STOP]
button.
b. When "The MC-80 may now be shut down safely"
appears in the display, turn off the power.
* Return the removed EXP COVER with the MC-80 to
customer.
* When using the VS4S-1 with the MC-80,
it has no reference to a VS4S-1 owner's manual including in
a VS4S-1 package.
However, return the owner's manual and the package with
the MC-80 to customer.
* "Zip(SCSI)" can be seen in VS4S-1 panel.
However,external SCSI hard disk drives can be also used
with no problem.
Feb,1999
Match up blue line on the fuji-card
with white line on the MC-80 JACK BOARD.
CN107
CN110
CN108
supplied fuji-card
8. ボトムカバーを取り付けます。
9. 動作チェックを行います。
a. あらかじめ外部 ZIP ドライブ、25 ピン SCSI ケーブルお
よびフォーマット済みのディスクを用意しておきます。
b. 外部 ZIP ドライブと SCSI コネクタを SCSI ケーブルで
接続します。
c. MC-80 の電源ケーブルを接続します。
d. 外部 ZIP ドライブの電源を投入します。
e. [CHAIN PLAY]+[REC]+[ARPEGGIATOR] を押しながら、
MC-80 の電源を投入します。
f. テストモードに入ったら、外部 ZIP ディスクを ZIP ドラ
イブに挿入します。
g. [F6(NEXT)] を押しデバイスチェックを行います。
h. SCSI アイコンが表示されなければ、動作は OK です。
SCSI アイコンが表示された場合は、以下の点をチェッ
クしてください。
-VS4S-1 のフジカードが正しく挿されているか?
SCSI
- 外部 ZIP ドライブが正しくつながれているか?
Dev Err!
- 外部 ZIP ドライブに ZIP ディスクが入っている
No Disk!
か?
10.シャットダウン操作を行います。
a. [SHIFT] を押しながら、[STOP] を押します。
b. "The MC-80 may now be shut down safely" と表示された
ら、電源を落としてください。
※ 取り外した EXP カバーは MC-80 とともにお客様に返却して
ください。
※ V S 4 S ‑ 1   が取り付けられた MC-80 を使用する上で VS4S-1 の
梱包箱に含まれている取扱説明書は関係ありませんが、 梱
包箱および取扱説明書は MC-80 とともにお客様に返却して
ください。
※ V S 4 S ‑ 1 には "Zip(SCSI)" と書いてありますが、SCSI タイプ
のハードディスクも問題なく使用できます。