Installation Requirements - Kohler K-1696 Installation Manual

Hide thumbs Also See for K-1696:
Table of Contents

Advertisement

Available languages

Available languages

Steam Outlet
17-3/4" (45.1 cm)
3/4" NPT
Pressure Relief

Installation Requirements

Model
Steam Control Kit (one kit required)
Required Electrical Service
Dedicated Circuit Breaker
Main Electrical Service
Main Circuit Breaker
Product Information
Weight
Size
Electrical Rating
Water supply
Water supply Shut-Off Valve
Steam Line
Pressure Relief Valve (supplied)
Sizing The Steam Room
Kohler Co.
Water Inlet
11-3/4"
(29.8 cm)
Field Wiring
Service Box
9-1/8"
(23.2 cm)
K-1696-NA
K-1647-PC OR
K-1737, K-638, and K-694 or
K-695
13 kW, 240 V, 70 A, 50/60 Hz
240 V, 70 A, 50/60 Hz
32 lbs (14.5 kg )
18" (45.7 cm) L x 12" (30.5 cm) x 13" (33 cm)
240 V, 60 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT
thread)
3/4" NPT female thread
447 cu. ft. (13 cu. m)
5
Minimum required access is 20" (50.8 cm)
L x 13" (33" cm) H x 6-1/2" (16.5 cm) W.
RJ-12
Control Jack
K-1713-NA
K-1647-PC OR
K-1737, K-638, and K-694 or
K-695
15 kW, 240 V, 100 A, 50/60 Hz
240 V, 100 A, 50/60 Hz
32 lbs (14.5 kg )
240 V, 70 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT
thread)
3/4" NPT female thread
500 cu. ft. (14 cu. m)
12"
(30.5 cm)
1053772-2-B