3.8.
Access Safety Hose
1. Remove baseboard, side baseboard, top panel and left side panel.
2. Remove clamp, cut the bound belt and disconnect the wire connector. Then the Inlet hose cane pulled out.
3. Reverse the above procedure to assemble.
Mechanical Aquastop hose is connected to appliance just as universal water inlet hose.
3.9.
Access Diverter valve
1. Disconnect power.
2. Remove bottom board.
3. Label and disconnect the 4 terminals.
4. Remove 1 screw fastening the diverter valve to sump.
5. Contrarotate the diverter valve to take it off.
6. Reverse the above procedure to install.
10