Promax BT-800K Operation Manual page 28

Belt type vacuum packaging machine
Table of Contents

Advertisement

Electrical diagram
BT-800K standard
COM 0
Y00
COM 1
GND
Y01
COM 2
Y02
Y03
COM 3
35
R1
Y04
R2
Y05
R3
Y06
R4
Y07
COM 4
35
SV1
Y10
SV2
Y11
SV3
Y12
SV4
Y13
COM 5
35
SV5
Y14
SV6
Y15
R5
Y16
BZ
Y17
35
AC24V
KM 1
OL1
R1
36
37
KM 2
OL2
R2
38
39
BK1
R3
R3
R2
40
41
KM 3
R4
42
KM 4
OL3
R5
43
44
PB2
L
F-555NT
35-1
R6
F-555NT
35-2
R7
BT-800K(TB)
P.L.C COM
FLAT BELT M OTOR CLOCKW ISE(M 0)
INVERTER (1st SPEED SIGNAL)(M 3)
INVERTER (2nd SPEED SIGNAL)(M 4)
17
VACUUM PUM P M OTOR
OUTFEED M OTOR CONTROL RELAY
FLAT BELT M OTOR
BREAKER CONTROL RELAY
SEALING HEATING
TOP COVER BOTTOM DOW N
CONTROL M AGNETIC VALVE
VACUUM
FILL GAS
SEALING BAR
VACUUM AIR OUTLET
INFEED CROSS BRIDGE
USED M AGNETIC VALVE
W ATER PUM P
BUZZER
VACUUM PUM P M OTOR
OUTFEED M OTOR CONTROL RELAY
T2
FLAT BELT M OTOR
BREAKER CONTROL RELAY
SEALING HEATING
STOP LIGHT
UP ELECTRO-THERM IC
CIRCUIT EXAM INA
DOW N ELECTRO-THERM IC
CIRCUIT EXAM INA
PB1
START
X00
PB2
STOP
X01
X02
RS1
CORVER LIM IT
X03
(LIFT SET)
RS2
M AGNETIC SENSOR
X04
(DOW N SET)
RS3
AGAINST LOSE
X05
(PREVENT COM PRESS FAILURE)
TL3~6
AGAINST SENSOR
(TOP COVER PREVENT
X06
COM PRESS DEVICE)
TL1
BELT M OTOR DECELERATION LIM IT
X07
TL2
BELT M OTOR LIM IT
X10
PS1
VACUUM AIR OUTLET
X11
Th1
BELT M OTOR OVERLOAD
X12
Th2
VACUUM M OTOR OVERLOAD
X13
Th3
OUTFEED M OTOR CONTROL RELAY
X14
Th4
W ATER M OTOR OVERLOAD SIGNAL
X15
R6
UP SEALING W IRE SIGNAL(BROKEN)
X16
R7
DOW N SEALING W IRE SIGNAL(BROKEN)
X17
26
X20
X21
X22
X23
X24
X25
X26
X27

Advertisement

Table of Contents
loading

Related Products for Promax BT-800K

Table of Contents