WillowWood ONE User Instructions

WillowWood ONE User Instructions

Transtibial system

Advertisement

Quick Links

WILLOWWOOD ONE®
TRANSTIBIAL SYSTEM
User
Instructions
QUICK-START GUIDE
1.
Don the Alpha Liner.
2. Don the One Gel Sock.
3. Don the prosthesis and pull the One Sleeve up onto your limb.
4. If your prosthesis has a LimbLogic® vacuum system, refer to the LimbLogic instructions
for details on operating the system.
5. Clean the liner and sleeve daily.
6. Disinfect the liner and sleeve weekly.
Note: Never store your prosthesis with the top half of the sleeve rolled back onto the socket edge.
Thank you for using the WillowWood One System. Please follow these steps to ensure the
most comfort and longest life from the system:
• Read and follow these instructions.
• Inspect your liner and sleeve after each day of use. Watch for signs of unusual wear. This
may indicate changes in the prosthetic fit. If you see unusual wear, call your prosthetist.
• Contact your prosthetist if you have any questions about the One System.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ONE and is the answer not in the manual?

Questions and answers

Summary of Contents for WillowWood ONE

  • Page 1 TRANSTIBIAL SYSTEM User Instructions Thank you for using the WillowWood One System. Please follow these steps to ensure the most comfort and longest life from the system: • Read and follow these instructions. • Inspect your liner and sleeve after each day of use. Watch for signs of unusual wear. This may indicate changes in the prosthetic fit.
  • Page 2 DO NOT PULL the liner onto the limb. Pulling the liner may stretch the gel, causing pulling on the skin and discomfort. 3. Invert the One Gel Sock so that the silicone side is facing out. Place the end of the inverted sock against the end of the liner.
  • Page 3 STORING THE LINER When the liner is not being worn, it should be stored with the logo side out in a cool, dry place. If the liner will not be used for a long time, cover the dry liner with a clean plastic bag. STORING THE SLEEVE When the prosthesis is not being worn, the bottom portion of the sleeve should be left on the socket.
  • Page 4: Daily Cleaning

    DAILY CLEANING Liner The liner must be thoroughly cleaned at the end of each day of wear and disinfected once each week. Note: Do not scrub the liner. Scrubbing can roughen the surface of the liner, which can then irritate the skin. Clean the inside and outside of the liner Dry the liner with a clean, Rinse all the soap residue...
  • Page 5 Sleeve If the silicone part of the One Sleeve touches your skin, it will need to be disinfected. Once a week, disinfect the area of the silicone that touches the skin. 1. Place a small amount of ethyl or isopropyl alcohol on a soft, clean cloth.
  • Page 6 Warning: To avoid danger of suffocation, keep this product away from babies or children. Warning: WillowWood One Transtibial System components have been designed and tested for use only with other WillowWood One Transtibial System components. Use with other sealing systems...
  • Page 7: Possible Issues

    System leaks. Sleeve fins torn. Replace sleeve. Holes in sleeve. Replace sleeve. Pump screws loose or missing. Call your prosthetist for repair. Loose One Link Cap with O-Ring. Tighten One Link Cap with O-Ring.
  • Page 8 The Ohio Willow Wood Company 15441 Scioto Darby Road Mt. Sterling, OH 43143 phone 740.869.3377 / 800.848.4930 fax 740.869.4374 www.willowwoodco.com Ohio Willow Wood Company B.V Keizersgracht 62/64 1015 CS Amsterdam The Netherlands PN-2497-C 27 MAR 2017...