WillowWood LIMBLOGIC M Prosthetist Instructions

Elevated vacuum suspension system

Advertisement

Quick Links

Prosthetist
Instructions
The LimbLogic M is an elevated vacuum suspension system that
operates by compressing with each step and is completely integrated
into the prosthesis without the annoyances of tubes in the socket.
The Ohio Willow Wood Company
15441 Scioto Darby Road
Mt. Sterling, OH 43143
phone 740.869.3377 / 800.848.4930
fax 740.869.4374
Ohio Willow Wood Company B.V
Keizersgracht 62/64
1015 CS Amsterdam
The Netherlands
Patent www.willowwoodco.com/
education-and-resources/patents
WHAT'S IN THE BOX
LimbLogic M
Proximal Gasket (2)
M6 X 50 mm Socket Head Capscrews (4)
Split Washer
LimbLogic 4-Hole Adapter
Forming Plate with 4 M6 X 10 mm Capscrews
Poron Filter
Instructions
LimbLogic M Prosthetist Instructions
LimbLogic M Patient Instructions
LimbLogic M Fabrication Instructions
www.willowwoodco.com
1
PN-2580-B 19 SEPT 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LIMBLOGIC M and is the answer not in the manual?

Questions and answers

Summary of Contents for WillowWood LIMBLOGIC M

  • Page 1 LimbLogic M Prosthetist Instructions LimbLogic M Patient Instructions LimbLogic M Fabrication Instructions The LimbLogic M is an elevated vacuum suspension system that operates by compressing with each step and is completely integrated into the prosthesis without the annoyances of tubes in the socket.
  • Page 2: Table Of Contents

    Unauthorized changes or modifications to the pump TABLE OF CONTENTS or accessories may impair their function resulting in Page injury or death, will void the warranty, and may Patient Criteria ......................4 prevent their compliance with relevant standards. Fitting Instructions .....................4 This pump is only designed to move air;...
  • Page 3: Patient Criteria

    Overview Overview PATIENT CRITERIA ASSEMBLY Indications Fabricate a laminated socket using the LimbLogic 4-Hole Adapter. Follow the fabrication instructions provided with Patients who meet the following criteria should be considered the adapter. for this system. Apply the proximal gasket to proximal surface of the •...
  • Page 4: Rotation Adjustment

    Overview Overview ROTATION ADJUSTMENT STIFFNESS ADJUSTMENT To make a rotation adjustment before assembling the In order to maintain alignment, make a reference mark to prosthesis, use an adjustable wrench to rotate the pyramid to indicate the rotation of the pyramid on the distal end of the desired position.
  • Page 5: Vacuum Level Adjustment

    Push the split washer up as proximal as possible on the shaft. The LimbLogic M features two settings for the vacuum level: Low and High. The pump is shipped with the setting at High. To change the Vacuum Level Setting to Low:...
  • Page 6: Patient Briefing

    Bolt the pump onto the socket with the M6 x 60 mm Do not allow children or pets to play with LimbLogic M or its bolts. accessories. While designed for durability, they may be damaged if exposed to untrained or rough handling.
  • Page 7: Operation At High Altitude

    • If a leak is detected: SERVICE LIFE Remove the pump. Install the Diagnostic Disc as The LimbLogic M pumps are designed for a reliable service life of shown. at least two years. WARRANTY Diagnostic The warranty for the LimbLogic M is two years from fit date.
  • Page 8: Regulatory Information

    Acceptable humidity range for long term USER PROFILE storage. Prosthetist user Acceptable pressure range for long term LimbLogic M is intended to be used for assembly of prosthetic storage. devices by a certified prosthetist or prosthetic technician. Patient user Consult instructions for use.