ClimateMaster Tranquility TC L Series Installation Operation & Maintenance

ClimateMaster Tranquility TC L Series Installation Operation & Maintenance

Table of Contents

Advertisement

Quick Links

Compact
High Capacity
(TC_L) Series
MODELS TC_LH072-120
TC_LV072-300
60 HZ - HFC-410A
INSTALLATION, OPERATION
& MAINTENANCE
97B0084N01
Revised: October 5, 2021
®

Table of Contents

3
4
6
7
8
9
10
11
12
13
14
15
16
18
21
22
23
26
29
30
31
32
33
34
36
38
42
46
47
48
49
50
51
52
53
54
56
57
58
59
62
63
64
65
67
69
70
71
74
75

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tranquility TC L Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ClimateMaster Tranquility TC L Series

  • Page 1: Table Of Contents

    Tranquility ® Compact High Capacity Table of Contents (TC_L) Series Model Nomenclature General Information TC_LH Physical Data (includes unit w/WSE) TC_LH072-120 Dimensional Data TC_LH072-120 w/WSE Dimensional Data TC_LV Physical Data (includes unit w/WSE) TC_LV072-120 Dimensional Data TC_LV072-120 w/WSE Dimensional Data TC_LV160-240 Dimensional Data TC_LV160-240 w/WSE Dimensional Data TC_LV300 Dimensional Data...
  • Page 2 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Table of Contents, Cont’d.
  • Page 3: Tranquility

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 4: General Information

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 General Information ⚠...
  • Page 5 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 6: Tc_Lh Physical Data (Includes Unit W/Wse)

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LH Physical Data Model Compressor Quantity...
  • Page 7: Tc_Lh072-120 Dimensional Data

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 8: Tc_Lh072-120 W/Wse Dimensional Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LH072-120 w/WSE Dimensional Data Discharge Connections Return Air Connections...
  • Page 9: Tc_Lv Physical Data (Includes Unit W/Wse)

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 10: Tc_Lv072-120 Dimensional Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV072-120 Dimensional Data Discharge Connection Return Air Connections Using...
  • Page 11: Tc_Lv072-120 W/Wse Dimensional Data

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 12: Tc_Lv160-240 Dimensional Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV160-240 Dimensional Data Discharge Connection Duct Return Air Connections...
  • Page 13: Tc_Lv160-240 W/Wse Dimensional Data

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 14: Tc_Lv300 Dimensional Data

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV300 Dimensional Data Discharge Connection Duct Return Air Connections...
  • Page 15: Tc_Lv300 W/Wse Dimensional Data

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 16: Horizontal Installation

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Horizontal Installation Horizontal Unit Location - Units are not designed for Mounting Horizontal Units...
  • Page 17 (e.g. louvered door). Therefore, filter rails are the industry service technician. If electric box relocated to opposite side, and water connected to opp 1.3” standard and are included on ClimateMaster commercial not required. [3.3cm] RIGHT RETURN RIGHT VIEW- LEFT RETURN LEFT VIEW- 1.3”...
  • Page 18: Tc_Lh Field Conversion Of Air Discharge

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LH Field Conversion of Air Discharge ⚠...
  • Page 19 motor bolts Remove 4 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y motor bolts Step 3 Tranquility Compact High Capacity ( TC _L) Series...
  • Page 20 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Horizontal Installation Figure 5: Right Return Side Discharge to Back Always vent the condensate line when dirt or air can...
  • Page 21: Vertical Installation

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 22: Tc_Lv Field Conversion Of Air Discharge

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV Field Conversion of Air Discharge ⚠...
  • Page 23: Tc_Lv072-240 Field Conversion Of Air Discharge

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 24 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV072-240 Field Conversion of Air Discharge, Cont’d.
  • Page 25 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 26: Tc_Lv300 Field Conversion Of Air Discharge

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV300 Field Conversion of Air Discharge Figure 9: TC_LV300 Top Discharge Steps to Convert to Straight Discharge Step 1 - Remove 5 panels, dividers, and panel...
  • Page 27 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 28 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV300 Field Conversion of Air Discharge, Cont’d.
  • Page 29: Tc_Lv Field Conversion Of Control Box

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 30: Tc_Lv Field Conversion Of Water Connections

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_LV Field Conversion of Water Connections ⚠...
  • Page 31: Vertical Condensate Installation

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 32: Piping Installation

    Optional pressure-rated hose assemblies designed Length specifically for use with ClimateMaster units are available. (2 ft [0.6m] Length Standard) C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s...
  • Page 33: Water-Loop Heat Pump Applications

    Hose kits are available the tower and the water loop is recommended. If an from ClimateMaster in different configurations as shown in open type cooling tower is used continuously, chemical Figure 13 for connection between the unit and the piping treatment and filtering will be necessary.
  • Page 34: Ground-Loop Heat Pump Applications

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Ground-Loop Heat Pump Applications ⚠...
  • Page 35 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 36: Ground-Water Heat Pump Applications

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Ground-Water Heat Pump Applications Open Loop - Ground Water Systems - Typical open loop Water Quality Standards - Table 3 should be consulted...
  • Page 37 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 38: Water Quality Standards

    All closed water loop systems should undergo water quality testing and be maintained to the water quality standards listed in this table. CLIMATEMASTER WATER QUALITY STANDARDS For Closed-Loop and Open-Loop Systems...
  • Page 39 R e v . : O c t o b e r 5 , 2 0 2 1 Water Quality Standards, Cont’d. 1. The ClimateMaster Water Quality Table provides Hydrogen Sulfide has an odor of rotten eggs. If one α...
  • Page 40 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Water Quality Standards, Cont’d.
  • Page 41 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 42: Electrical - Line Voltage

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Electrical –...
  • Page 43 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 44 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Electrical –...
  • Page 45 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 46: Electrical - Power Wiring

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Electrical –...
  • Page 47: Electrical - Power & Low Voltage Wiring

    24 Volt signals and not line voltage. temperature when using an antifreeze solution. All Terminal “A” is energized with the compressor contactor. ClimateMaster units operating with entering water See the specific unit wiring diagram for details. temperatures below 59°F [15°C] must include the...
  • Page 48: Electrical - Low Voltage Wiring

    120 Valve high pressure switch shall have a cut-out pressure of 300 psig and a cut-in pressure of 250 psig. This pressure switch can be ordered from ClimateMaster with a 1/4” internal flare connection as part number 39B0005N02. Thermostat...
  • Page 49: Electrical - Thermostat Wiring

    CXM or DXM control board. Practically any heat pump temperature measurement. Position the thermostat back thermostat will work with ClimateMaster units, provided plate against the wall so that it appears level and so the it has the correct number of heating and cooling stages.
  • Page 50: Typical Wiring Diagram - Tc_L Units With Cxm

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Typical Wiring Diagram –...
  • Page 51: Typical Wiring Diagram - Tc_L Units With Mpc

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 52: Typical Wiring Diagram - Tc_L Units With Dxm

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Typical Wiring Diagram –...
  • Page 53: Cxm Controls

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 54: Dxm Controls

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 DXM Controls DXM Control - For detailed control information, see Not Clipped = 30°F [-1°C].
  • Page 55 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 56: Safety Features

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Safety Features Safety Features –...
  • Page 57: Cxm And Dxm Controls

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 58: Blower Adjustment

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Blower Adjustment ⚠...
  • Page 59: Vfd Operation

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 60 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 VFD Operation, Cont’d.
  • Page 61 ATC32U thermostat the installer/service technician stage of cooling and automatically switch the fan to the can; check and set CFM; ClimateMaster works continually higher fan speed setting. This system may be further to improve its products. As a result, the design and enhanced with a humidistat.
  • Page 62: Tensioning V-Belt Drives

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Tensioning V-Belt Drives Figure 22: Tensioning V-Belt Drives General Rules of Tensioning...
  • Page 63: Blower Sheave Information

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 64: Tc_L072 Blower Performance

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_L072 Blower Performance All Data is Wet Coil SCFM...
  • Page 65: Tc_L096 Blower Performance

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 66 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_L096 Blower Performance, Cont’d.
  • Page 67: Tc_L120 Blower Performance

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 68 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 TC_L120 Blower Performance, Cont’d.
  • Page 69: Blower Performance Data - Tc_Lv160 Standard Unit

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 70: Blower Performance Data - Tc_Lv192 Standard Unit

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Blower Performance Data –...
  • Page 71: Blower Performance Data - Tc_Lv240 Standard Unit

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 72 C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Blower Performance Data –...
  • Page 73 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 74: Blower Performance Data - Tc_Lv300 Standard Unit

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Blower Performance Data –...
  • Page 75: Unit Starting And Operating Conditions

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 76: Piping System Cleaning And Flushing

    Models with Waterside Economizer also manually open economizer valve and coil air vents (2) to bleed air from coil. 4. Verify that all strainers are in place (ClimateMaster recommends a strainer with a #20 stainless steel wire mesh). Start the pumps, and systematically check each vent to ensure that all air is bled from the system.
  • Page 77: Unit Starting And Operating Conditions

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 78: Unit Start-Up Procedure

    Slowly raise the thermostat to a higher temperature 5. Two factors determine the operating limits of until the compressor activates. ClimateMaster heat pumps, (a) return air temperature, Check for warm air delivery within a few minutes and (b) water temperature. When any one of these after the unit has begun to operate.
  • Page 79 T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 80: Unit Operating Conditions

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Unit Operating Conditions Operating Pressure/Temperature tables include the •...
  • Page 81: Start-Up Log Sheet

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 82: Preventive Maintenance

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Preventive Maintenance Water Coil Maintenance - Condensate Drain - In areas where airborne bacteria...
  • Page 83: Circuit Diagram With Safety Devices

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 84: Functional Troubleshooting

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Functional Troubleshooting Fault Possible Cause...
  • Page 85: Performance Troubleshooting

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 86: Functional Troubleshooting - I-P Units

    C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S Tranquility Compact High Capacity ( TC _L) Series ® R e v . : O c t o b e r 5 , 2 0 2 1 Functional Troubleshooting –...
  • Page 87: Warranty (U.s. & Canada)

    T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact High Capacity ( TC _L) Series ®...
  • Page 88: Revision History

    ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.

This manual is also suitable for:

Tc lh072-120Tc lv072-300

Table of Contents