Trip & LED Bliking Information
6. Current Trip and LED Blinking 6 times (Current Trip)
Blink
Blink Blink Blink Blink Blink
Æ Purpose : Protection Over-Current(Over-Load)
Æ Cause : Abnormally ambient temperature(Over 43℃), Abnormally conditions like Shield machine room etc.
Condenser Fan failure, Comp. failure, PCB failure(IPM breakdown)
Oil shortage of the cylinder, Cylinder or Piston damage, clogging the discharge, Comp. internal debris.
Æ Logic : After the Comp. Off every 6 minutes restart Comp.
Test Mode
LED 6
Reset
Blinks
OF
F
About 5min
1 Input
N
LED 6
Comp.
Blinks
Action?
Y
Check
Cycle
leakage
-13-
N
PCBA Output
Replace PCB
> 60V
Y
Check Comp.
Copyright © 2021 LG Electronics Inc. All rights