TABLE OF CONTENTS PAGE PAGE 1 Safety Precautions -----------------------------------------------3 1.1. General Guidelines ----------------------------------------3 1.2. Leakage Current Cold Check ---------------------------3 1.3. Leakage Current Hot Check (See Figure 1.)--------3 1.4. How to Discharge the E.Capacitor on the Frame Unit ---------------------------------------------------4 2 Warning --------------------------------------------------------------5 2.1.
1 Safety Precautions 1.3. Leakage Current Hot Check (See Figure 1.) 1.1. General Guidelines 1. Plug the AC cord directly into the AC outlet. Do not use 1. IMPORTANT SAFETY NOTICE an isolation transformer for this check. There are special components used in this equipment 2.
1.4. How to Discharge the E.Capacitor on the Frame Unit CAUTION: 1. Make sure to discharge the E.capacitor on the Frame Unit. 2. Be careful of the high voltage circuit on the Frame Unit when servicing. [Discharging Procedure] 1. Refer to the disassemble procedure and remove the necessary parts/unit. 2.
2 Warning 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. The following techniques should be used to help reduce the incidence of component damage caused by electrostatic discharge (ESD).
3 Service Navigation 3.1. Introduction This service manual contains technical information, which allow service personnel’s to understand and service this model. Please place orders using the parts list and not the drawing reference numbers. If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual. 3.2.
3.4. How to Define the Model Suffix (NTSC or PAL model) There are six kinds of DMC-LZ20, regardless of the colours. • a) DMC-LZ20P • b) DMC-LZ20E • c) DMC-LZ20EE • d) DMC-LZ20GN • e) DMC-LZ20GK • f) DMC-LZ20PU/GC/GF/GW What is the difference is that the “Initial Setting” data which is stored in Flash-ROM mounted on MAIN P.C.B.. 3.4.1.
Page 8
3.4.2. Initial Setting 1. Execute the Sales Area Setting Tool 2. Connect the DSC to PC by USB cable 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
6 Service Fixture & Tools 6.1. Service Fixture and Tools The following Service Fixture and tools are used for checking and servicing this unit. REMARKS 1. ABOUT “LIGHT BOX”:...
7 Disassembly and Assembly Instructions 7.1. Disassembly Flow Chart This is a disassembling chart. When installing, perform this chart conversely. 7.2. PCB Location...
Page 19
7.3.6. Removal of the Lens Unit 7.3.7. Removal of the Front Case Unit NOTE: When Disassembling and Installing for the Lens Unit 1. Take care that the dust and dirt are not entered into the lens. In case of the dust is putted on the lens, blow off them by airbrush.
Page 20
(Fig. D17) 7.3.8. Removal of the Speaker Unit (Fig. D18) (Fig. D16)
Page 21
7.3.9. Removal of the Plate L 7.3.11. Removal of the SW P.C.B. (Fig. D21) NOTE: (When Installing) Make sure to confirm the following points when installing: • The Screw is tightened enough. • Installing conditions are fine. (No distortion, no abnormal- space.) •...
7.4. Lens unit 7.5. Lens Disassembly Procedure Precaution: 7.4.1. Lens unit parts 1. Do not remove the CCD Unit when disassembling or reassembling the lens in order to maintain it clean. 2. Keep dust or dirt away from the Lens. 3.
Page 23
7.5.2. Removal of the L Washer and the O 7.5.4. Removal of the IR Filter Washer 7.5.3. Removal of the Lens Rubber...
8 Measurements and Adjustments 8.1. Introduction When servicing this unit, make sure to perform the adjustments necessary based on the part(s) replaced. To perform the adjustment, it is necessary to use the “SPCA5330_v1010.exe” and “CK26100WriteQRCodeTool.exe” software. The Adjustment software “SPCA5330_v1010.exe” and “CK26100WriteQRCodeTool.exe” are available at “TSN Website”. 8.2.
Page 27
8.3.2. USB driver installation 1. Execute the Setup Launcher 2. Connect the DSC to PC by USB cable 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
Page 28
8.3.3. MB/LCD Function Check 1. Setting the DSC 1. Set the battery to the camera. 2. Insert the SD card. 3. Turn off the power. 4. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 5.
Page 29
8.3.5. OB Calibration 1. Setting the DSC 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
Page 30
8.3.7. MeShut(LV13/LV14) Calibration 1. Setting the DSC 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
Page 31
8.3.9. Light / S.S / Preview Calibration 1. Setting the DSC 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
Page 32
8.3.11. Write Lens QR Code 1. Execute the Write QRCode Tool 2. Connect the DSC to PC by USB cable 1. Set the battery to the camera. 2. Turn off the power. 3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically. 4.
9 Maintenance 9.1. Cleaning Lens and LCD Panel Do not touch the surface of lens and LCD Panel with your hand. When cleaning the lens, use air-Blower to blow off the dust. When cleaning the LCD Panel, dampen the lens cleaning paper with lens cleaner, and the gently wipe the its surface. Note: The Lens Cleaning KIT ;...
11 Wiring Connection Diagram 11.1. Interconnection Schematic Diagram FLASH OPEN TOP CASE UNIT BUTTON FRAME UNIT LENS UNIT SW P.C.B. (FOIL SIDE) MICROPHONE CCD UNIT MOTOR FLASH FPC AF LED MIC1 AFLED1 SPEAKER VCOM LEDA LEDK HSYNC VSYNC DCLK LCD UNIT Vint1 VINT2 VCOML...
Page 38
Model No. : DMC-LZ20 Schematic Diagram Note...
Page 48
Model No. : DMC-LZ20 GYRO (Main P.C.B. 9/14)
Page 49
Model No. : DMC-LZ20 USB (Main P.C.B. 10/14)
Page 50
Model No. : DMC-LZ20 Motor / PT5113 (Main P.C.B. 11/14)
Page 51
Model No. : DMC-LZ20 OSI / AT5571 (Main P.C.B. 12/14)
Page 52
Model No. : DMC-LZ20 UI / Strobe / LED (Main P.C.B. 13/14)
Page 53
Model No. : DMC-LZ20 POWER (Main P.C.B. 14/14)
Page 54
Model No. : DMC-LZ20 Main P.C.B. (Component side)
Page 55
Model No. : DMC-LZ20 Main P.C.B. (Foil side)
Page 56
Model No. : DMC-LZ20 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks VUAVG0E00001 VUAVG0E00002 VUAVG0E00003 VUAVG0E00003 VUAVG0E00004 VUAVG0E00005 VUAVG0E00006 VUAVG0E00007 VUAVG0E00008 VUAVG0E00009 VUAVG0E00010 VUAVG0E00011 VUAVG0E00012 VUAVG0E00013 ERBRE2R00V FUSE ERBRE2R00V FUSE ERBRE2R00V FUSE VUAVG0E00014 CRYSTAL OSCILLATOR VUAVG0E00015 CRYSTAL OSCILLATOR VUAVG0E00016 CRYSTAL OSCILLATOR...
Page 57
Model No. : DMC-LZ20 Frame and Casing Section...
Page 58
Model No. : DMC-LZ20 Packing Parts and Accessories...
Page 59
Model No. : DMC-LZ20 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks VUAVG0P00001 MAIN PCB VUAVG0P00002 SW PCB VUAVG0M00001 TOP CASE UNIT VUAVG0M00002 FRONT CASE UNIT 1 (-K) VUAVG0M00003 FRONT CASE UNIT 1 (-R) VUAVG0M00015 GRIP PIECE FRONT VUAVG0M00004 REAR CASE UNIT 1 (-K)
Page 60
Model No. : DMC-LZ20 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks VUAVG0S00008 SCREW VUAVG0S00008 SCREW VUAVG0S00008 SCREW VUAVG0S00008 SCREW VUAVG0S00008 SCREW VUAVG0S00009 SCREW VUAVG0S00009 SCREW VUAVG0S00010 SCREW VUAVG0S00010 SCREW VUAVG0S00010 SCREW VUAVG0S00010 SCREW VUAVG0S00011 SCREW VUAVG0S00013 SCREW VUAVG0S00013...