Charge Mode - Lemania Energy FLASH Series User Manual

Battery charger / battery support
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4

CHARGE MODE:

The chargers advanced software is optimized to correctly and completely charge a wide variety of battery types and chemistries;
including lead acid (Flooded, AGM, EFB, GEL) and Lithium (LiFePo4) starting batteries from 20Ah to 1200Ah.
Once the CHARGE Mode is selected, the charging voltage, battery type and charging voltage can be entered.
Ensure that the input parameters (nominal voltage, battery type, charging current) are correct for the battery that you are
attempting to charge, that they meet the battery manufacturer's specifications and that you have read the battery's recharging
instructions. Failure to respect the battery specifications may result in damage to the charger, the battery, the vehicle,
property, or personal injury.
Charging Mode operation
4.1 Smart Charging Process:
Important: Ensure the selected mode and parameters match the type of battery you are attempting to charge
9-stage charging process for Lead Acid Batteries:
Battery Condition Analysis→ De-Sulphation (if needed) → Soft-Start → Bulk Charge→ Analysis1 →Absorption→ Analysis2
→ Equalization → Float Charge→ (21 Days reset period)
Step
1:Press
Step 2: Press
Step 3: Press
to Start or Stop the charging process.
Displayed values during charging:
Charging Percentage: indicates percentage of charge (%).
Current: displays the charging current (A)
Voltage: displays the charging voltage (V)
Ah: displays the Amp-hours recharged.
Time: displays the duration of charge
9
to ENTER or EXIT the charge mode
to Select the desired parameter
Fig -2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf35Sf150

Table of Contents