  • Page 1: Table Of Contents

    ..........E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de 811.523 BA / EN...
  • Page 2: Safety Information

    Instruction Manual for Electroblock EBL 271 Safety information Meaning of the safety symbols DANGER! Failure to comply with this sign may result in danger to life and limb. WARNING! Failure to comply with this sign may result in injury. ATTENTION! Failure to comply with this sign may result in damage to the device or other connected consumers.
  • Page 3: Introduction

    Instruction Manual for Electroblock EBL 271 Introduction This instruction manual contains important information for safe operation of the device. Make sure you read and follow the safety instructions provided. The instruction manual should always be kept in the vehicle. All safety infor- mation must be passed on to other users.
  • Page 4: Changing The Battery

    Instruction Manual for Electroblock EBL 271 Generator operation and passenger vehicle ferries ATTENTION! The electroblock, 12V consumers and the connected devices can be da- maged if the thresholds for the 230V supply are exceeded. Note therefore the following: It is essential that the generator conforms to the specifications of the mains supply.
  • Page 5: Operating Faults

    If this is not possible, e.g. if you are abroad, you can have the electroblock repaired at a specialist workshop. In this case you must ensure that the war- ranty is not invalidated by incorrect repairs being carried out and Schaudt GmbH will not accept any liability for damage resulting from such repairs.
  • Page 6 Instruction Manual for Electroblock EBL 271 Fault Possible cause Remedy Living area battery is not No mains voltage Switch on the automatic charged during 230V ope- d d i 230V circuit breaker in the vehi- ration (battery voltage ration (battery voltage cle;...
  • Page 7: Closing Down The System

    Instruction Manual for Electroblock EBL 271 Fault Possible cause Remedy 12V supply does not work 12V main switch for the li- 12V main switch for the li- in the living area in the living area ving area battery is swit...
  • Page 8: Application And Functions In Detail

    Instruction Manual for Electroblock EBL 271 Application and functions in detail The EBL 271 electroblock is the central power supply unit for all 12V consu- mers in the vehicle’s electrical system. It is usually located in a cupboard or storage area and is accessible from the front to change fuses.
  • Page 9: Battery Functions

    Instruction Manual for Electroblock EBL 271 Battery functions Suitable batteries 6-cell lead acid or lead gel batteries, 55 Ah and above Battery charging Simultaneous charging of the starter battery and the living area battery via whilst moving the alternator, parallel connection of the batteries via a cut-off relay...
  • Page 10: Additional Functions

    Instruction Manual for Electroblock EBL 271 Additional functions Refrigerator controller This output can be used to continually supply an existing refrigerator control- ler. Awning light The power supply to this consumer is automatically interrupted as soon as the engine starts running (the D+ connection is live in this case or switched to ground, depending on the type of vehicle).
  • Page 11: Appendix

    Instruction Manual for Electroblock EBL 271 Appendix EC declaration of conformity Schaudt GmbH hereby confirms that the design of EBL 271 electroblock complies with the following relevant regulations: EC low voltage directive 2006/95/EC dated 12.12.2006 Electromagnetic compatibility directive 2004/104/EC dated 14.10.2004 2005/49/EC dated 25.07.2005...
  • Page 12 Instruction Manual for Electroblock EBL 271 Fault report In the event of damage please fill in the fault report and send with the faulty device to the manufacturer. Device type: _______________________ Item no.: _______________________ Vehicle: Manufacturer: _______________________ Model: _______________________ Own installation?
  • Page 13 Instruction Manual for Electroblock EBL 271 Design Fig. 3 Layout of the EBL 271 electroblock (front) Block 8: IT ... / LT ... control and switch panel Block 1: Refrigerator Block 7: Aux 3...6, fold-away bed, marker lights D+ signal changeover switch...
  • Page 14 Instruction Manual for Electroblock EBL 271 Block diagram/wiring diagram Charging relay Battery 1 MNL socket, 2F block 3 Auxiliary charger LAS 1218 14.3V--18A Battery cut--out relay, 70A Changeover switch Mains 230V~50Hz lead gel/ IEC connector lead acid S 1218 + Starter battery (batt.1) + living area battery (batt.2)