Table of content EC Declaration of Conformity ........................3 General Description of the Machine ......................4 Specified Conditions of Use .......................... 5 Residual risks ..............................5 Notes on Transport ............................5 Use and Conditions for Storage........................5 Before Initial Operation ..........................6 Operation ..............................
General Description of the Machine Fig. 1 Components of the Machine: Remote control Remote control cable Hydraulic fluid filler cap Pressure adjustment valve Manometer Fluid level sight glass Hose coupling connection "A" Hose coupling connection "B" Mains cable with mains plug Manual actuation for solenoid valve Fluid drain plug...
Specified Conditions of Use This device is exclusively intended for use as a drive mechanism for hydraulic torque tools in line with professional the description and safety instructions given in these Operating Instructions. Any other use is considered to be improper! In particular the use of the machine as a drive for all other hydraulic devices such as presses, hoisting ...
Before Initial Operation Carry out a visual inspection before each start-up. Check remote control (1), mains plug (9) and all cables for damage. Check hose couplings, hoses and hydraulic torque tools for damage. not included in delivery Hose couplings, hoses and hydraulic torque tools must be designed for an operating pressure of 700 bar.
Operation Operating the Machine Switch on the motor by actuating the white push-button on the remote control (1). White push-button actuated: forward stroke of the tool piston White push-button not actuated: return stroke of the tool piston ...
Servicing and Fault Clearance As a matter of principle, electrical work may only be carried out by qualified electricians. Use only original spare parts as per the spare parts list. Hydraulic fluid change and filter change (if fitted) at least once every year or at the latest after every 300 operation hours;...
Technical Data Fig. 5 FE055-3-230V Type Technical Data Voltage 1~230V 50Hz Nominal power output 0,55 kW Pump capacity: Low pressure < 75 bar 6.5 l/min Medium pressure 75-220 bar 1.8l/min High pressure up to 700bar 0.7 l/min Weight without/with hydraulic fluid...
Part List for Hydraulic Diagram Part List / Stückliste FE055-3-230V Part N° Denomination Type Characteristics Manufacturer / Supplier 10006 Pressure Relief Valve MVE4 AR 12l/min; 700bar HAWE 10009 Pressure Relief Valve DBV 100 5l/min; 250bar Stephan Dahlmann M.u.A. GmbH 10010...