Samsung DVE45T6200 Series User Manual page 24

Hide thumbs Also See for DVE45T6200 Series:
Table of Contents

Advertisement

Available languages

Available languages

Installation
STEP 3 Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the "Electrical
requirements" section on page 18.
3-wire system
A
B
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. 3/4" (1.9 cm) UL-listed strain relief
24
English
Untitled-3 24
1. Loosen or remove the center terminal
2. Connect the neutral wire (white or
3. Connect the other wires to outer
C
D (N)
4. Tighten the strain relief screws.
L1
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system
• Ring-type terminals are recommended.
• Connect the power cord and check L1/
block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
L2/N voltage. If the voltage is low, It
may not dry properly.
2020-02-13
1:01:17

Advertisement

Table of Contents
loading

Table of Contents