Series Deco-Tube Model BTD-ETO100 Infrared Patio Heater nstallat tion, Op peration n and S Service Instruc ctions RNING: FO OR OUTDOO OR USE O ONLY WARNING DANG Improper in nstallation, adjustmen t, alteration If you smell l gas: service or maintenanc ce can cau se injury or...
Caution and General Safety CAUTION: FIRE OR BURN INJURY HAZARD At all times maintain clearance to combustible materials as further specified in this manual. Failure to do so can result in serious fire hazard. Never operate heaters in atmosphere containing flammable vapours or combustible dusts. This heater is equipped with an electronic and automatic ignition device.
General Installation Codes Installations must comply with local building codes, or in their absence, the latest edition of the national regulations and procedures as listed below. General Installation and Gas Codes Heaters must be installed only for use with the type of gas appearing on the rating plate, and the installation must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the US and CAN/CGA B149.1 and B149.2 Installation Codes in Canada.
Installation Requirements Clearance to Combustibles A general clearance of 18” (0.5 m) in every direction is recommended for servicing only around each Burner, also to ensure adequate air flow in and around the Heating System. In addition to this it is very important to observe the minimum clearance to combustibles at all times to avoid any possibility of property damage or personal injury.
Page 12
Installation Requirements Model No.: Reflector Configurations ETO-100 Horizontal 4" 29" 73.5" 29" 45° Reflector Tilt 8" 2.5" 55.5" 43" Ends (both sides) ” 4 This heater can be installed between wood beams with minimum distances as shown. Air flow MUST NOT Trusses CAN'T be inclosed Wood Beam 1/2"...
Installation Requirements Heater Mounting RECOMMENDED hanging equipment needed to install the heater. In all cases, check with local codes for seismic bracing requirements for outdoor heating equipment. In these instructions we illustrate installation with angles and a combination of angles and turnbuckles.
Installation Instructions Installation Sequence: Generally, there is no unique sequence for installation of the burner or heat exchanger. A review of the job site will usually indicate a logical installation order. However, time and expense can be saved if installation is begun at the most critical dimension, watching for interference from overhead beams etc.
Page 15
Installation Instructions Step 2: 60.0" 90.0" Pipe stand Step 3: Pipe stand Flanged tube /25/2013 DECO-T PRIL ERIES...
Page 18
Installation Instructions Step 8: 4' Extension tube Torque to 15-25 ft-lbs When installing, orient band clamp lock bolts to side at 3 o'clock or 9 o'clock position to avoid contact with reflector. Step 9: Vent hanger /25/2013 DECO-T PRIL ERIES...
Page 20
Installation Instructions Step 12: Slide reflector and hanger against flange Step 13: #8-32 X 3/8" screws DECO-T /25/2013 ERIES PRIL...
Page 21
Installation Instructions Step 14: Baffle Bend tab over end of tube at 6 o'clock position Step 15: #8 X 1/2" self drilling screws Vent terminal assembly Push vent terminal assembly over baffle tab. Secure vent terminal assembly to tube using self drilling screws.
Page 23
Installation Instructions Step 18: Use turnbuckles or angle iron to secure heater into angle irons anchored to ceiling. /25/2013 DECO-T PRIL ERIES...
Page 24
Installation Instructions Step 19: Use turnbuckle to secure heater to ceiling angle iron. Gasket -Heater (Burner). -Use 5/16 washers and nuts to attach burner to flanged tube. Step 20: Deco-Grille DECO-T /25/2013 ERIES PRIL...
Installation Instructions Drop Ceiling Installation: Continue on from step 19 Drop ceiling installation WITH metal border Metal border Deco grille Metal border Min. 3.0" Deco grille Max. 11.0" /25/2013 DECO-T PRIL ERIES...
Page 29
Installation Instructions Deco-Grille Installation continued: Drop ceiling installation WITH REFLECTOR Shield (No Metal Border) Reflector shield (cut to fit deco-grille sections) Deco-Grille Ceiling Tiles Reflector shield (cut to fit deco-grille sections) Min. 3.0" Ceiling Tiles Max. 5.75" /25/2013 DECO-T PRIL ERIES...
Page 30
Installation Instructions Deco-Grille Installation continued: Drop ceiling installation WITHOUT REFLECTOR Shield (No Metal Border) Non-Combustible Ceiling Tiles Deco grille Non-Combustible Ceiling Tiles Min. 3.0" Deco-Grille DECO-T /25/2013 ERIES PRIL...
Installation Instructions Venting This heater does not require venting as it is approved for OUTDOOR INSTALLATION ONLY. WARNING! This heater is NOT approved for any indoor Residential application. If in doubt of your application consult with your local fire marshal or gas authority having jurisdiction. Indoor spaces include but are not limited to attached garages, solariums, living quarters etc.
Gas Connections Installation / Code Requirements Installation must comply with local building codes and/or, for the USA/National Fuel Gas Code, ANZI Z 223.1 (NFPA 54) and for Canada, CAN/CGA B149.1 and B149.2, National Gas and Propane Installation Code (latest editions). Appliance must be electrically grounded in accordance with local codes or, in their absence;...
Wiring Diagrams General Requirements Heaters are normally controlled by line voltage (120V) or low voltage (24V) thermostats. Line voltage thermostats are wired directly while low voltage thermostats use a relay. In all cases, heaters must be grounded in accordance with the National Electric Code, ANSI/NFPA 70 in the US, and the Canadian Electric Code, CSA C22.1 in Canada, and must comply with all local requirements.
Page 34
Wiring Diagrams The following diagram is an OPTIONAL one, use when Module 50X-24 Channel Module is supplied. ETO - Wiring Diagram (OPTIONAL) THERMOSTAT IS MOUNTED EXTERNALLY STAT Brown Yellow (1) Blue Yellow (2) M HI Brown Brown FIRE Brown Yellow LAMP LOW FIRE LAMP Yellow...
Wiring Diagrams External Wiring Options Manual Line Switch with Hi-LO wiring diagram Notes: - Using 2 Toggle switchs Hi (on) - Allow Min. contact rating of 1AMP per heater inductive. - Allow 20VA / 24V. transformer Low (On) per heater. Yellow (Hi) 24 Volt Transformer...
Lighting & Shutdown Instructions Lighting 1. Open manual gas supply valve (ensure gas supply lines have been purged). 2. Turn on switch to energize electric supply. 3. The blower motor will energize. 4. When the motor approaches nominal running RPM, the air-proving switch closes and activates the ignition module.
Maintenance & Trouble Shooting Maintenance For best performance, the certain minimal maintenance procedures should be performed before each heating season: Before performing any services or maintenance, shut off gas and electrical supply to heater. Check condition of forced air blower scroll and motor. Dirt and dust may be blown or vacuumed from the blower.
Page 38
Maintenance & Trouble Shooting Trouble shooting continued… Burner Does Not Light Is spark visible through site glass during ignition trial? If no, further electrical checks by a qualified service person are required. Check to see if gas lines were properly purged of air. ...
Warranty SERIES -TUBE PATIO HEATER WARRANTY The Manufacturer warrants to the original owner that the product will be free of defects in material and workmanship for a period of 5 years from the date of purchase, for everything except the blower, electronic control module, spark electrode, and sense electrodes which have a replacement warranty period of 3 years.