  • Page 1 ® AQUATRAP LGR Dehumidifier Model AT150R OPERA TING MANUAL READ AND STUDY MANUAL BEFORE USE...
  • Page 2: Declaration Of Conformity

    Electromagnetic Compatibility: emission requirement. LVD : EN 60335 - 1: 2002+A1:2004+A11:2004+A12:2006+A2:2006 Safety of household and similar electrical appliance General requirements. EN 60335 - 2-40: 2003+A11:2004+A12:2005+A1:2006 Particular requirements for electric heat pumps, air conditioners and dehumidifiers. Abatement Technologies Design and Development...
  • Page 3: Safety Instructions

    Abatement Dehumidifiers are used by professionals for the drying out of wet materials such as carpets, carpet cushions, floors, walls, building contents and more. They reduce the water in enclosed structural environments like buildings or parts of a building by removing water vapor from the air. Safety Instructions •...
  • Page 4 Create a closed drying chamber The dehumidifier should be operated in an enclosed space in order to create a drying chamber. Close all doors, windows or areas that open to the outside to maximize the unit’s water removal efficiency. Inside the drying chamber, air should circulate freely.
  • Page 5: Operating Your Dehumidifier

    Operating Your Dehumidifier Place the dehumidifier in upright position If the dehumidifier has been laid down in a horizontal position for any time over a few minutes, you must set it upright (vertical) for 30 minutes before starting. Connect the drainage system You can find the hose wrapped around the back of the machine.
  • Page 6 How to Use the Touch Pad Control Panel Touch pad control panel Includes: • one LCD Display, • one Indicator Light (Red/Green) and • five touch pad keys for dehumidifier operations. LCD Display: DEHUMIDIFIER ON. PURGE ON. The pump is on and pumping water out of the condensate reservoir.
  • Page 7 Touch Pad Keys: ON/OFF. Press the ON/OFF key to turn the machine on or off.  When the machine is turned on, it comes on in STANDBY MODE. The red indicator light and LCD light up. LCD displays the “TIMER” CLOCK icon. Four time digits flash, which prompts the operator to either set the “TIMER”...
  • Page 8 Touch Pad Keys (Cont.): PURGE. Press the PURGE key to empty water from the pump reservoir. During normal operation, the pump purges automatically whenever the reservoir is full. The display will show the PURGE ON icon. PURGE PUMP MANUALLY BEFORE TRANSPORTATION: ...
  • Page 9: Maintenance

    The machine will revert to STANDBY MODE but will still be on unless manually turned off. Contact Abatement Technologies for service.  When Er03 error message displays, the dehumidification cycle is still on. Contact Abatement Technologies for service. Indication Light: Status Colors Description Machine is off.
  • Page 10: Warranty

    Periodic Inspections (as needed) Make sure the unit is unplugged. Remove housing, in order to locate the coil, pump and drain hose. • Check coil and clean visible dirty  Vacuum both sides of the coils until clean. • Check pump ...
  • Page 11: Specifications

    21.65 in / 550mm Depth 17.91 in / 455mm 84 lbs / 38 kg Use Weight Specifications are subject to change without notice. Some values are approximate. Abatement Technologies Tel: 800 – 634 – 9091 Fax: 800 – 358 – 2394 iaqinfo@abatement.com...