CXA2211 (2/2)
Adjustment
Mode OSD
CXA2211
Sync Processor
019
This is switch a switch that selects the
route of LPF in the sync sep circuit.
This is valid when AUTO = 1
020
00h = Through, 01h = LPF
021
022
023
Sync separation circuit slice level setting
This is valid when HSEPSEL = 1
00h = Automatic setting
024
01h = H fixed to 65% from the sync tip.
02h = H fixed to 25% from the sync tip.
025
03h = ***
026
Adjustment Item
480i
480p
1080i
720p
480i
480p
1080i
720p
88
Initial Data(HEX)
Adjustment
Range(HEX)
DP55
00~01
00
00~01
00
00~01
00
00~01
00
00~03
01
00~03
01
00~03
01
00~03
01