Download Print this page
VITRA 310 - 2111 Installation Manual

VITRA 310 - 2111 Installation Manual

Electronic concealed flush valve for urinals

Advertisement

Quick Links

www.vitra.com.tr
Head Office
VitrA Bathroom Group
Eczacýbaþý Yapý Gereçleri San. ve Tic. A.Þ.
Kanyon Ofis Kat: 20 -21
Büyükdere Cad. No:185
39394, Levent, Ýstanbul / TURKEY
Tel: +90-212 371 74 00
Fax:+90-212 371 78 33
Installation Montage
ELECTRONIC CONCEALED FLUSH
VALVE FOR URINALS
(MAIN SUPPLY)
310 - 2111 MATT CHROME
310 - 2112 CHROME PANEL
310 - 2113 SATIN CHROME PANEL
313124

Advertisement

loading
Need help?

Need help?

Do you have a question about the 310 - 2111 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VITRA 310 - 2111

  • Page 1 Eczacýbaþý Yapý Gereçleri San. ve Tic. A.Þ. Kanyon Ofis Kat: 20 -21 Büyükdere Cad. No:185 39394, Levent, Ýstanbul / TURKEY 310 - 2111 MATT CHROME Tel: +90-212 371 74 00 310 - 2112 CHROME PANEL Fax:+90-212 371 78 33 310 - 2113 SATIN CHROME PANEL...
  • Page 2: System Specifications

    Installation Montage Installation Montage SYSTEM SPECIFICATIONS User free operation in public places. Hygiene. Ability fort he handicapped people. FEATURES System Works with optical sensation (infrared beams) principle. The main parts are the body, battery cover, solenoid valve group and panel mounted electronic module.
  • Page 3 Installation Montage Installation Montage NOTES: ASSEMBLY If lid is used for urinal system should be installed higher than the lid’s standing position. Use filter before the systems. Assembling should be made by an authorized plumber.
  • Page 4 Installation Montage Installation Montage NOTES: 431400 431200 431318 431316 431700 431105 431109 431106 431112 431317 424315 Grup / Parça Adý Grup / Parça Adý 424315 Urinal Connection Pipe with Seal 431317 Photocell Module 431105 Solenoid Plug 431318 Transformer 431106 Frame 431400 Body Box 431109...
  • Page 5: Warranty Conditions

    The products shall be inspected upon receipt. VitrA should be informed immediately due to any detectable defect. VitrA is entitled to inspect any damage at any time, together with third parties for the 230V purpose of determining damage and any possible cause. If the inspection is refused by the purchaser/end user, any liability for defects will be extinguished.
  • Page 6 Installation Montage Installation Montage MAINTANCE CHART Failure: System does not flush. Check the transformer. Power on the power plug? Does red light flush after 2 sec. Unless user come in range? Check the Does red light flash after 1 sec. If a user Check the connection.
  • Page 7 Installation Montage Installation Montage CONTROL Before you open the panel, please be sure, if your main power turn off against risk of electric shock. DRAWING 1 WITHOUT PRE WASH DRAWING 2 WITH PRE WASH...
  • Page 8 Installation Montage Installation Montage...

This manual is also suitable for:

310 - 2112310 - 2113