  • Page 1: Room Air Conditioner

    Room Air Conditioner OWNER'S MANUAL Prior to installation, this air- conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm). IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. •...
  • Page 2: Table Of Contents

    Room Air Conditioner Owner’s Manual TABLE OF CONTENTS Safety Precautions...3 Prior to Operation ...5 Operating Instructions...6 Remote Controller ...6 Remote Control Operation ...7 Maintenance and Service ...12 Indoor unit...12 Outdoor unit...12 Operation Tips ...13 Troubleshooting ...14 2 Room Air Conditioner FOR YOUR RECORDS Write the model and serial numbers here: Model #...
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION Meanings of symbols used in this manual are as shown below.
  • Page 4 Safety Precautions Ventilate before operating air conditioner when gas goes out. • It may cause explosion, fire and, burn. Never touch the metal parts of the unit when removing the filter. • They are sharp and may cause injury. When cleaning the unit, first make sure the power and breaker are turned off.
  • Page 5: Prior To Operation

    Prior to operation Preparing for operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6.
  • Page 6: Operating Instructions

    Operating Instructions Operating Instructions Remote Controller Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. Reattach the cover by sliding it back into position. NOTICE Use 2 AAA(1.5volt) batteries.
  • Page 7: Remote Control Operation

    Remote Control Operation The remote control transmits the signals to the system. TEMP. TIME (1) Operation Mode Cooling Operation Healthy Dehumidifacation Operation (Cooling Model) (2) Operation Procedure Start/Stop Button Operation Mode Selection Button Room Temperature Setting Button Indoor Fan Speed Selection Button OPERATION DISPLAY Displays the operation conditions.
  • Page 8: Cooling Operation

    Operating Instructions Cooling Operation Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling. TEMP. TIME Natural wind by the CHAOS logic For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
  • Page 9 Heating Operation(Heat pump model only) TEMP. TIME Timer control Setting OFF TIMER CONTROL SETTING TEMP. TIME Press the Start/Stop button. The unit will respond with a beep. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
  • Page 10: Jet Cool Operation

    Operating Instructions Jet Cool Operation TEMP. TIME NOTICE During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp.
  • Page 11: Vertical Airflow Direction Control

    Vertical Airflow Direction Control The up/down airflow (Vertical Airflow) can be adjusted by using the remote control. 1. Press the Start/Stop button to start the unit. 2. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.
  • Page 12: Maintenance And Service

    Maintenance and Service Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. Indoor Unit Grille, Case, and Remote Control Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
  • Page 13: Operation Tips

    When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. Turn off the circuit breaker, and disconnect the plug. CAUTION CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time.
  • Page 14: Troubleshooting

    Maintenance and Service Troubleshooting Check the following points before requesting repairs or service... If the fault persists, please contact your dealer or service center. Case The air conditioner does not operate. The room has a peculiar odor. It seems that condensation is leaking from the air conditioner.