Alignment Instructions - Panasonic RF-2400 Service Manual

Hide thumbs Also See for RF-2400:
Table of Contents

Advertisement

Volume control VR.
- DC voltage measurements are taken with electronics voltmeter.
The negative terminal of the battery provides negative meter
connection point.
No mark.........
FM
( ).....................
AM
- Battery current:
Vol. min................
FM: 8.8mA (DC) / 3.9mA (AC)
AM: 6.0mA (DC) / 3.7mA (AC)
Vol. max...............
FM: 210mA (DC) / 7.8mA (AC)
AM: 200mA (DC) / 7.6mA (AC)
Measurement instruction
AM:
74dB/m, 30% Mod.
FM:
60dB, 30% Mod.
- Important safety notice
Components identified by
importan for safety. / When replacing any of these components,
use only manufacturer's specified parts.
- This shematic diagram may be modified at any time with the
development of new technology.
3.2. Schematic Diagram
4. Printed Circuit Boards
5. Measurements and Adjustment

5.1. ALIGNMENT INSTRUCTIONS

mark have special characteristics
9

Hide quick links:

Advertisement

Table of Contents
loading