Lennox Allied Air A95DF1D Installation Instructions Manual page 26

Warm air gas furnace
Table of Contents

Advertisement

2" EXTENSION FOR 2" PVC PIPE
1" EXTENSION FOR 3" PVC PIPE
FURNACE
INTAKE
PIPE
Figure 34. Flush Mount Side Wall Termination
7.
If intake and exhaust piping must be run up a side
wall to position above snow accumulation or other
obstructions, piping must be supported every 24" (610
mm) as shown in Figure 39.
When exhaust and intake piping must be run up an
outside wall, the exhaust piping must be terminated
with pipe sized per Table 9. The intake piping may be
equipped with a 90° elbow turndown. Using turndown
will add 5 feet (1.5 m) to the equivalent length of the
pipe.
8.
Based on the recommendation of the manufacturer, a
multiple furnace installation may use a group of up to
four terminations assembled together horizontally, as
shown in Figure 37.
EXHAUST
VENT
12" (305mm)
Minimum
Above Average
Snow
Accumulation
CLAMP
Figure 35. Direct Vent Concentric Rooftop
Termination
Page 26 of 51
FURNACE
EXHAUST
4''
PIPE
GLUE EXHAUST
END FLUSH INTO
TERMINATION
FLAT
1-1/2" ACCELERATOR
SIDE
(
all -45, -070 and -090 units)
1 1/2" (38mm) accelerator
provided on 71M80 & 44W92
FLASHING
INTAKE
(Not Furnished)
AIR
SHEET METAL STRAP
(Clamp and sheet metal strap
must be field installed to support
the weight of the termination kit.)
FIELD-PROVIDED
REDUCER MAY BE REQUIRED
TO ADAPT LARGER VENT
PIPE SIZE TO TERMINATION
FIELD-PROVIDED
REDUCER MAY BE REQUIRED
TO ADAPT LARGER VENT
PIPE SIZE TO TERMINATION
EXHAUST
VENT
INTAKE
AIR
Figure 36. Direct Vent Concentric Wall Termination
Figure 37. Optional Vent Termination for Multiple Unit
Installation of Direct Vent Wall Termination Kit
(203MM - 305MM)
Minimum 12" (305MM)
above chimney top
plate or average snow
accumulation
* SIZE TERMINATION PIPE
PER EXHAUST PIPE TERMINATION
SIZE REDUCTION TABLE
NOTE: Do not discharge exhaust gases directly into any chimney or
vent stack. If vertical discharge through an existing unused chimney
or stack is required, insert piping inside chimney until the pipe open
end is above top of chimney and terminate as illustrated. In any
exterior portion of chimney, the exhaust vent must be insulated.
Figure 38. Direct Vent Application Using Existing
Issue 1917
1-1/2" (38mm) accelerator
provided on 71M80 & 44W92
kits for -45 and -70 units
OUTSIDE
INTAKE
WALL
AIR
INTAKE
CLAMP
AIR
(Not Furnished)
GRADE
ANGLE-CUT IN DIRECTION
3"-8"
(76MM-203MM)
8" - 12"
INTAKE PIPE
SHOULDER OF FITTINGS
PROVIDE SUPPORT
INSULATION (optional)
OF PIPE ON TOP PLATE
SHEET
METAL TOP
PLATE
3" - 8"
(76MM-
203MM)
INSULATE
TO FORM
SEAL
Chimney
EXHAUST
VENT
12" (305mm) Min.
above grade or
average snow
accumulation.
STRAIGHT-CUT OR
OF ROOF SLOPE
ALTERNATE
INTAKE PIPE
EXTERIOR
PORTION OF
CHIMNEY
507271-02