Troubleshooting - l-com RS-422 User Manual

Table of Contents

Advertisement

USB to RS-422 / RS-485 Adapter

Troubleshooting

1. Windows 2000 cannot find drivers for my device
This error can occur if the VID and PID programmed into the device EEPROM do not match those listed in
the INF files for the driver. The VID and PID programmed into
the device EEPROM may be found by using the USBView utility from the FTDI web site. These can then be
checked against the VID and PID entries in the driver INF files. If they do not match, that driver cannot be
installed for that device without either re-programming the device EEPROM or modifying the list of VID and
PID numbers in the INF files. Please note that only your own company VID and PID or FTDI's VID (0x0403)
and FTDI PID issued for use by your company should be used in the EEPROM and INF/INI files.
2. Windows 2000 forces a reboot after installing a device
This problem can occur if an application is accessing a file while the New Hardware Wizard is trying to copy
it. This usually occurs with the FTD2XX.DLL file. Selecting
not to restart the computer then unplugging and re-plugging the device may allow the device to function
properly without restarting. Restarting the machine will allow the device to work correctly.
Driver installation fails and Windows 2000 gives error code 10
3.
Windows error code 10 indicates a hardware error or failed driver installation. This
error may appear if a device has insufficient power to operate correctly (e.g. plugged into a bus powered hub
with other devices), or may indicate a more serious hardware problem. Also, it may be indicative of USB root
hub drivers being incorrectly installed. Please refer to the example schematics on the FTDI web site for
standard device configurations.