nRF24L01+ 2.4GHz TTL
Auto Frequency Hopping Module

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E34-2G4H20D

  • Page 1 E34-2G4H20D nRF24L01+ 2.4GHz TTL Auto Frequency Hopping Module...
  • Page 2: Table Of Contents

    5.1 Default parameter......................................15 5.2 Parameter setting instruction..................................15 5.3 Reading operating parameters..................................18 5.4 Reading version number....................................18 5.5 Reset instruction......................................18 6. Parameter setting........................................19 7. Customization.........................................20 Revision history..........................................20 About us............................................. 20 Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 3 No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by EBYTE at any time. For most recent documents, visit www.ebyte.com.
  • Page 4: Introduction

    Chengdu Ebyte Electronic Technology Co.,Ltd. E34-2G4H20D User Manual 1. Introduction 1.1 Feature E34-2G4H20D is a 100mW wireless transceiver module, which operates at 2.4-2.518GHz. The outstanding advantages of this module is concentrated power densities, long transmission range, automatic frequency hopping &strong anti-interference, TTL level.
  • Page 5: Electrical Parameter

    -40 ~ +85℃ temperature Operating humidity 10% ~ 90% Relative humidity, no condensation Storage temperature -40 ~ +125℃ Receiving Sensitivity has nothing to do with serial baud rate or -102dBm@250kbps sensitivity timing Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 6: E34 Series

    Plug-in E34-DTU 232/485 2.4G 250k~2M Screwing/ DB9 (2G4H20) E34-2G4H20D is compatible with other E34 series 1.4 FAQ Question Description Low air rate is recommended, the higher the air rate ,the shorter the range and Air data rate higher data loss.
  • Page 7: Uart Functional Description

    The receivers under target channel will receive data.. Only 1 data packet length is supported for fixed transmission (refer to electrical parameters); If the data exceeds 1 data packet length, it will be sub-packed automatically. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 8: Broadcast Address

    1. For example, set module A address as 0xFF FF and channel as 0x04. 2. When module A is receiver (transparent mode), it with data sent by all modules with channel 0x04. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 9: Functional Description

    Can be configured as open-drain output or push-pull output (floating is allowed). Power supply 2.3V-5.5V DC Ground Fixing hole Fixing hole Fixing hole Fixing hole Fixing hole Fixing hole Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 10: Connect To Mcu

    AUX Pin can be used as indication for wireless send & receive buffer and self-check. It can indicate whether there are data that are yet to send via wireless way, or whether all wireless data has been sent through UART, or whether the module is still in the process of self-check initialization. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 11 Notes: When AUX = 1, it does not mean that all the UART data of the module have been transmitted already, perhaps last packet data still transmission. 【Configuration procedure of module】 Only happened when power-on resetting or exiting sleep mode. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 12 When the user switches to other operating modes from mode 3 (sleep mode) or it ’s still in reset process, the module will reset user parameters, during which AUX outputs low level. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 13: Operating Mode

    This operation is very flexible and efficient. It is totally designed on the basis of the user MCU’s convenience, at the same time the work load and power consumption of the whole system has been reduced and the efficiency of whole system is largely improved. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 14: Fixed Frequency Mode (Mode 0)

    4.4 Reservation mode (Mode 2) When M1 = 1 & M0 = 0, module works in mode 2. The same as that in mode 0. Transmitting The same as that in mode 0. Receiving Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 15: Sleep Mode (Mode 3)

    Plug mode-select jumper in the USB test board (M1 = 0, M0 = 0), make the module work in mode 0. Optional power supply, 3.3V or 5V (it supports 2.3V ~ 5.5V). Operate AccessPort software and select the correct serial port code. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 16: Instruction Format

    When multiple same addresses exist, conflict may occur, please set as 0. ---------------------------------------- ---------------------------------------- Default 0 3, 2, 1, 0: high address(default F0H) ADDL Low address of module (default 00H) 00H-FFH (the default 00H) Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 17 Fixed frequency mode(mode 0) 0-5 Communication frequency : 2400M + CHAN * 2M 6-11 Communication frequency : 2508M + (CHAN-6)* 2M Frequency hopping mode(mode 1) 0-11 Communication frequency : 2412M + CHAN * 2M Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 18 For example: The meaning of No.3 "SPED" byte: The binary bit of the byte The specific value (user configures) Meaning UART parity bit 8N1 UART baud rate is 9600 Air data rate is 250k Corresponding hexadecimal Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 19: Reading Operating Parameters

    During the reset process, the module will conduct self-check, AUX outputs low level. After reset completing, the AUX outputs high level, then the module starts to work regularly which the working mode can be switched or be given another instruction. Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 20: Parameter Setting

    Please operate the “Fifth step” if you need to reconfigure, Complete the o if the configuration is completed, peration please click "ClosePort" and then take off the module. Commands Parameter configuration is also available for MCU (in mode 3). Configuration Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 21: Customization

    Linson About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------------------ Fax: 028-64146160 Web: www.ebyte.com Address: B5 Mould Industrial Park, 199# Xiqu Ave, High tech Zone, Chengdu, Sichuan, China...