Electric Wiring; Fan Belt; Adjusting Fan Belt Tension - Kubota WG972-G-E3 Operator's Manual

Kubota liquid cooled gasoline/lpg engine
Table of Contents

Advertisement

26
PERIODIC SERVICE

ELECTRIC WIRING

To avoid personal injury or death:
C Shorting of electric cable or wiring
may cause a fire.
A Check to see if electric cables and
wiring are swollen, hardened or
cracked.
A Keep dust and water away from all
power connections.
Loose wiring terminal parts, make
bad connections. Be sure to repair
them before starting the engine.
Damaged wiring reduces the capacity of electrical parts.
Change or repair damaged wiring immediately.

FAN BELT

BAdjusting fan belt tension
To avoid personal injury or death:
A Be sure to stop the engine and
remove the key before checking the
belt tension.
A Be sure to reinstall the detached
safety shield after maintenance or
checking.
A deflection of between 7.0 to 9.0 mm
Proper fan belt
(0.28 to 0.35 in.) when the belt is
tension
pressed in the middle of the span.
1. Stop the engine and remove the key.
2. Apply moderate thumb pressure to belt between the
pulleys.
3. If the measurement is not within the factory
specifications, loosen the alternator mounting screws
and relocate the alternator to adjust.
4. Replace fan belt if it is damaged.
A If belt is loosen or damaged and the fan is damaged,
it could result in overheats or insufficient charging.
Correct or replace belt.
(1) Fan belt
(A) 7.0 to 9.0 mm (0.28 to 0.35 in.)
(under load of 10 kgf (22.1 lbs))