Orantech SpO2 User Manual

Orantech SpO2 User Manual

Veterinary probe
Hide thumbs Also See for SpO2:

Advertisement

Quick Links

The difference you can sense
Veterinary SpO2 Probe
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SpO2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Orantech SpO2

  • Page 1 The difference you can sense Veterinary SpO2 Probe User Manual...
  • Page 2: Intended Use & Indications For Use

    (SpO2) and pulse rate (PR). These compatible replacement sensors are intended for use with major pulse oximeter brands. The SpO2 sensors are designed to match the specifications of the original equipment manufacturer, therefore confirm that the appropriate sensor model numbers are being used with the correct pulse oximeter technology.
  • Page 3: Installation

    Installation • Connect the SpO2 to the oximeter’s adapter cable (or SENSOR directly into the monitor). • Turn the oximeter on and verify proper operation. • Select the sensor site on the patient. The preferred sensor sites are the tongue or anus for animal.
  • Page 4 All user and patient accessible materials are non-toxic. • The pins of plug must not be in contact with the cleaning fluid, otherwise it will cause permanent damage to the SpO2 sensor . Equipment • Connect the sensor adapter cable to the appropriate equipment (or pulse oximeter).
  • Page 5 SpO2 range (70%~100%) -Accuracy ±3% SpO2 range (<70%) -Not specified Pulse rate range: 35~240 bpm -Accuracy ±2 bpm Low perfusion: SpO2 range (70%~100%) -Accuracy ±3% Pulse rate range: 35~240 bpm -Accuracy ±3 bpm • Peak Wavelength and Maximum Output Power:...
  • Page 6: Cleaning And Disinfecting

    Degree of protection against the ingress of water: IPX2 • Compatibility In order to ensure compatibility and claimed accuracy of the devices, the SpO2 should only be used with the specified SENSOR equipment for which they have been designed and labeled for use.
  • Page 7: Storage And Handling

    Do not irradiate, autoclave, soak or immerse the sensor in any kind of solution. Keep the sensor clean and dry. The average life expectancy of a SpO2 is more than a SENSOR year under the conditions of use defined in these operating instructions.
  • Page 8: Shelf Life

    Shelf Life 5 years. Warranty & Liability Orantech offers 12 months warranty against defects in material or workmanship from the date of purchase. But does not include the damage or breakage due to the abusive use or negligent care of the sensors.
  • Page 9 • Significant levels of dysfunctional hemoglobins, such as carboxyhemoglobin or methemoglobin, will affect the accuracy of the SpO2 measurement. • Any condition that restricts blood flow, such as use of a blood pressure cuff or extremes in systemic vascular resistance, may...
  • Page 10 • Use multiple sensor sites. Under certain clinical conditions, pulse oximeters may display dashes if unable to display SpO2 and/or pulse rate values. Under these conditions, pulse oximeters may also display erroneous values. These conditions include, but are not limited to: patient motion, low perfusion, cardiac arrhythmias, high or low pulse rates or a combination of the above conditions.
  • Page 11: Waste Disposal

    MR scanner. Caution Federal (U.S.) Law restricts this device to sale by or on the order of a physician. Waste Disposal Please refer to your local laws and regulations for information on how to dispose of SpO2 SENSORS...
  • Page 12: Definition Of Symbols

    Definition of Symbols...
  • Page 13 Support To get the support, please contact the representative of manufacturer or local distributor. Thecategoriesshown belowareavailable forsalethroughthelocaldistributorsore-commerce. SpO2 NIBP TEMP EtCO2 FETAL Orantech Inc. Zone#A, 4F,1st Bld, 7th Industrial Zone, YulvCommunity, GongMing, GuangmingNew District,Shenzhen, China 518106 www.orantech.com info@orantech.com REF: (+86) 7552369 9939 M20-M006-01 Cables and Sensors B.V.