U P S
Uninterruptible Power System
Line Interactive (Network) UPS
1000VA/ 1200VA/ 1500VA/ 2000VA /3000VA
■ ■ USER'S MANUAL■ ■
- 1 -
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING (SAVE THESE INSTRUCTIONS):
contains important instructions that should be followed during installation
and maintenance of the UPS and batteries.
● The unit is intended for installation in a temperature-controlled, indoor
area free of conductive contaminants.
● Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from batteries.
● When replacing battery, replace with the same number and type.
CAUTION:
Do not dispose of battery or batteries in a fire, the battery
may explode.
CAUTION:
Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
CAUTION:
A battery can present a risk of electric shock and high
short circuit current. The following precaution should be observed when
working on batteries:
Remove watches, rings or other metal objects.
Use tools with insulated handles.
Wear rubber gloves and boots.
Do not lay tools or metal parts on top of batteries.
Disconnect charging source prior to connecting or disconnecting
battery terminals.
CAUTION:
To reduce the risk of fire, connect only to a circuit provided
with 20 amperes maximum branch circuit overcurrent protection, in
accordance with the National Electrical Code. ANSI/NFPA 70.
This manual
- 2 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1000VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Roline 1000VA

  • Page 1 Do not open or mutilate the battery or batteries. Released ● Line Interactive (Network) UPS electrolyte is harmful to the skin and eyes. It may be toxic. 1000VA/ 1200VA/ 1500VA/ 2000VA /3000VA CAUTION: A battery can present a risk of electric shock and high ●...
  • Page 2 Table of contents For model with RS-232 port as communication port Important Safety Instructions ................2 Table of contents ....................3 Introduction......................3 1. Presentation..................... 3 2. Installation....................... 4 3. Operation......................5 4. Alarm ......................5 5. Software and Interface Port(Option)..............6 Appendix a Troubleshooting ................
  • Page 3 3. Operation Attention: The rapid alarm under “LOW BATTERY” condition cannot be muted. 3.1 Switch on with “Green Mode” Function under AC mode 4.3 “OVER LOAD” (continuous alarm): When utility input is connected to the UPS, press “ON” button and keep pressing less than 1 sec to turn When the UPS is working under overload condition (the connected loads exceed the maximum rated on the UPS.
  • Page 4 Model 1000A/AP 1200A/AP 1500A/AP 2000A/AP 3000A/AP Audible Noise <40dBA (1 meter from surfac <50dBA Storage Condition 15,000 meters max. Capacity 1000VA 1200VA 1500VA 2000VA 3000VA 110V, 115V, 120V/ 220V, 230V, 240V, +/-25% at line input Input Voltage (3000A/AP Only for 220V 230V 240V)