Download Print this page
Galvin Engineering Ezy-Push CP-BS Lead Safe Product Installation

Galvin Engineering Ezy-Push CP-BS Lead Safe Product Installation

Timeflow push button replacement cartridge – adjustable

Advertisement

Quick Links

Product Installation Guidelines
CP-BS Lead Safe™ Timeflow Push Button
®
Ezy-Push
Replacement Cartridge – Adjustable
(Suit 173.61.55.00 and TP08045PA)
PRODUCT CODES:
- 173.92.55.00
SPECIFICATIONS
The Ezy-Push
Smooth round designs to facilitate easy clean and help reduce dirt and bacteria growth.
Water saving, easy to operate and low maintenance.
Adjustable time flow.
IMPORTANT: All Ezy-Push
premises in good working order.
Note: Run
time is based on 500kPa, 5 litres per minute @ 22 degrees Celsius. Time will vary plus or minus
30% based on water temperatures, pressures, flow rates and water quality.
As 'lead free' is not currently defined by low in Australia and New Zealand, we have based our definition of Lead Safe™ on the requirements of s1417 of the USA's Safe Drinking Water Act
(SDWA) and the relevant US standards NSF61 / NSF372. The SDWA defines 'lead free' as "not more than a weighted average of 0.25% lead when used with respect to the wetted surface of
pipes, pipe fittings, plumbing fittings and fixtures".
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Construction
Finish
Time (s)
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
© Galvin Engineering Pty Ltd
®
time flow cartridge has a unique self-closing operation.
®
Push Button taps are tested in accordance with AS/NZS 3718 and leave our
Version 1.1, 13 May 2021, Page 1 of 4
M26 x 19 TPI - Male
N/A
Time Flow Cartridge
Min
100
Max
500
Min
5
Max
65
N/A
Brass
Chrome
0 – 30 Adjustable

Advertisement

loading

Summary of Contents for Galvin Engineering Ezy-Push CP-BS Lead Safe

  • Page 1 Working Pressure Range (kPa) Working Temperature Range (°C) Nominal Flow Rate (LPM) Construction Brass Finish Chrome 0 – 30 Adjustable Time (s) NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. © Galvin Engineering Pty Ltd...
  • Page 2 Tighten the cartridge assembly down firmly. Do not over tighten as this could restrict or stop the flow. If this occurs loosen the cartridge by ¼ of a turn. − Connect the water lines & turn on water. Check for leaks and correct operation. © Galvin Engineering Pty Ltd...
  • Page 3 (not supplied) 3. Fix position 4. Reassemble − Orientate the stop ring to allow the refitting − Reassemble completely paying attention to of the grub screw align the hole in the spindle with the grub screw © Galvin Engineering Pty Ltd...
  • Page 4 WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.

This manual is also suitable for:

Ezy-push lead safe 173.61.55.00