Ont grounding implementation

Advertisement

Calix ONT Grounding
Implementation
January, 2007
# 220-00178, Rev 10

Advertisement

loading

Summary of Contents for Calix 500 Series

  • Page 1 Calix ONT Grounding Implementation January, 2007 # 220-00178, Rev 10...
  • Page 3: Table Of Contents

    Contents Introduction................5 Grounding Purpose..............5 NEC and Grounding ..............6 Testing the Earth Electrode.............7 Full-of-Potential Method ............9 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 4 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 5: Introduction

    This document details the National Electrical Code (NEC) requirements for properly grounding an ONT during installation. This document also provides specific information for installing the ground on the Calix 500- Series or 700-Series ONTs, on the following models: ONT Type...
  • Page 6: Nec And Grounding

    A bonding jumper of #6 AWG copper must be used between the two electrodes. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 7: Testing The Earth Electrode

    Ground Bond #6 AWG UL Listed Clamp Earth Electrode Earth Layers 5229 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 8 AC Voltage Source Volt/Ohm Meter Test Rod “C” Test Rod “P” Earth 5225 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 9: Full-Of-Potential Method

    The presence of electrical currents in or near a ground system will compromise the overall integrity of the grounding system. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © 2001-2007 Calix. All Rights Reserved.
  • Page 10 Calix recommends that the testing of grounds be conducted on a preventative maintenance schedule to insure the maximum safety possible. Maintenance records should be kept for each ONT installation. In some locations, extremely high earth ground resistance is present. In these locations, chemicals that lower earth resistance can be added to the earth that surrounds the electrode.