2.0 Installation, continued
C. Remove the plug from the bottom of the Brass Cross and replace with item C
(Hex Bushing, Check Valve and Tube Fitting).
D. Remove the Valve Stack Cover. Locate the Blank located in slot two and loosen
the single Mounting Screw. The Blank should now lift out easily. Replace with the
Soap Option Valve (item D).
Remove label
and the blank.
Replace
the blank
with Item D
21-11-1008
Item C
Section 2 – 2