3. Examine the air filter and replace it if it is necessary.
CAUTION:
or blow compressed air on it. This will do
damage to the air filter.
4. Replace the air filter if it is necessary.
a) Loosen the screw on the air filter housing and
remove it.
Problem
The product does not start.
1631 - 001 - 04.05.2021
Do not clean the air filter

Troubleshooting

Cause
The start procedure is done incor-
rectly.
The stop switch in the right (STOP)
position.
There is no fuel in the fuel tank.
The spark plug is defective.
The clutch is defective.
b) Install the new air filter.
5. Attach the air filter cover and tighten the 3 screws.
To do a check of the water supply
system
1. Examine the nozzles on the blade guard and make
sure that they are not clogged.
2. Clean as necessary.
3. Examine the filter on the water connector. Make sure
that it is not clogged.
4. Clean as necessary.
5. Examine the hoses and make sure that they are not
damaged.
Possible solutions
To start the product with a cold en-
Refer to
gine on page 23 and To start the product
with a warm engine on page 25 .
Make sure that the stop switch (STOP) is in
the left position.
Fill with fuel.
Replace the spark plug.
Speak to your service agent.