Installer and user Programming Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CE2N-416 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fracarro CE2N-416

  • Page 1 CE2N-416   Installer and user Programming Manual...
  • Page 2: Table Of Contents

    LA-LB (line) and DA-DB (phone): telephone line connection page Feeder connection page 5.4 Electrical safety warnings page 6 First switching ON of the CE2N-416 control unit: page 7 CE2N-416 Control Unit Programming page 7.1 Programming keys page 7.2 Installer code’s features (default 0000000) page 7.3 Master code’s features (default 1111111)
  • Page 3 8.4 Clock page 8.5 Historic log page 8.6 Test page Lines being tested page Output function test page Walk test page Walk test tamper page Channel test page DTMF reception test page 8.7 Exclusions page 9 Reset page 9.1 Reset the keypad serial number with a zero address page 9.2 Restore factory settings page...
  • Page 4: Safety Warnings

    Fuse identification: Fuse F300: F 3.15A. 1. DESCRIPTION OF THE FEATURES This chapter lists the main hardware and functional features of the CE2N-416 unit and the different elements and accessories that complete it. Main features The control unit lines can be expanded to 4 with a M4IBUS module or to 8 with a M8IBUS module.
  • Page 5: Other Features

    Up to 4 remote keypads for managing the system and totally/partially arming the system. Firmware updating from PC (locally) with a MOD-USB interface module. 250 stored events can be displayed with the date/ time/user/event displayed with the set name for better tracking. Partialization, even by means of an electronic key, with RFID technology (up to 4 readers for a total of 16 total keys).
  • Page 6: Ce2N-416 Control Unit Layout

    - +13.8V EXT_SIR : 500mA. N.B. The total absorption at the outputs +13.8V EXT_SIR and +V_INT_SIR and BUS power must not exceed 500mA. Lead battery: 2Ah 12V 3. CE2N-416 CONTROL UNIT LAYOUT 1: Feeder 2: Control unit card 3: Battery 4: Cable passage holes 4.
  • Page 7 box of the telephone line. • The control unit must be installed on the wall in a position that makes it easy to access the electric cables, telephone cable, system alarm harness as well as to perform maintenance on the control unit. •...
  • Page 8: Card Description

    5. CARD DESCRIPTION 5.1 Component description Terminal boards Input terminal from the feeder Terminal board for connecting inputs, outputs and power sources of the various devices connected to the control unit (see the specifi c chapter) Terminal board for connecting the peripheral units connected to the BUS Terminal board of input (LA-LB LINE) and output (DA-DB PHONE) of te- lephone line Jumper...
  • Page 9: Keys

    Keys S500 RESET key: press this key for a few seconds to reboot the microproces- sor of the control unit after a block and/or an anomaly. This operation DOES NOT cancel the programming and system settings S501 DEFAULT key: Press the “Default” and “Reset” keys simultaneously to re- store the factory settings and cancel all the settings of the control unit.
  • Page 10: J4 Terminal Board

    OUT4 Open collector output, which can be programmed. Negative in the event of activation. Max 50mA OUT3 Open collector output, which can be programmed. Negative in the event of activation. Max 50mA OUT2 Open collector output, which can be programmed. Negative in the event of activation.
  • Page 11: Examples Of Terminal Connections Page

    5.3 Examples of terminal connections L1, L2, L3, L4: alarm line inputs These terminals are connected to the contacts of the alarm detection devices. These inputs can be individually programmed as: • Normally closed • Normally open • Single balancing •...
  • Page 12: Ref: 12V "Reference" Output

      +REF: 12V “reference” output; this output is missing during an alarm event   Terminal with voltage that is always available but is missing when an alarm is generated. Voltage is still available after the programmed alarm time is over or when the system is deactivated.
  • Page 13: Feeder Connection

    • Fuse identification: Fusibile F300: F 3.15A. 6. FIRST SWITCHING ON OF THE CE2N-416 CONTROL UNIT In this phase, we recommend not connecting the wires to the “+V_INT SIR” terminal and “+ REF” terminal in order to prevent the activation of the indoor and outdoor sirens.
  • Page 14 7.3 Master code’s features (default 1111111) ATTENTION: for programming the Master code, refer to the User Master section in paragraph 10 The CE2N-416 system allows the user to have 1 master code with a variable length between 2 and 7 figures.
  • Page 15: Programmable Parametres

    8. PROGRAMMABLE PARAMETERS Installer code 0000000 Ref. 8.1 - page 16: from this menu, you can set all the Control unit configuration parameters of lines, outputs, partitions, dialer and the various settings of the system. Ref.8.2 - page 31: from this menu, all modules connected to the BUS, such as keypads, electronic key readers, line Modules modules and speakerphone module, are acquired and...
  • Page 16: Lines

    “integration time” defines the time by which the control unit must count the “impulse number” set in the item of the previous menu. Wire: The CE2N-416 control unit can connect a roller wire contact directly to the line input without using any additional analysis card.
  • Page 17 Standard: setting for all traditional detectors, such as volumetric sensors or perimeter contacts. Vibration: The CE2N-416 control unit can directly connect to a vibration contact at the line input without using any other additional analysis card. Def. Load. V=yes X=no: all the default parameters of this line type will be loaded.
  • Page 18 Input time: in the condition of activated system, if an alarm is generated on a delayed line, the count of the set input time is activated (each delayed line has its own input time that is from 0 to 255 sec.). Within this interval, the control unit does not generate an alarm, provided that the other no-delayed lines (instantaneous, internal instantaneous, etc.) do not cause an alarm.
  • Page 19 prevents the keypads and the readers from working because the line “requires” the activation and does not allow other control devices from being deactivated. - Line termination: After defining the typology of the line and all the other subparameters that define the line type, the line termination will have to be defined.
  • Page 20: Outputs

      Line 1 Line type Line termination Line name 8.1.2 Outputs The control unit is equipped with 5 outputs that can be programmed freely.   Paste on…. Select the line • +REF, live output with positive reference that is configured at 12V when the system is not generating an alarm (the output is mainly used for the external self-powered siren control) •...
  • Page 21 Activation duration: the duration of the output under an alarm can be defined for the impulse outputs Manual output: enables the output to be displayed for the manual activation from the keypad or telephone. The modes to activate the manual outputs of the CE2N-416 are as follows:...
  • Page 22: Partitions

    • By remote telephone access, • Key lines. Output name: the CE2N-416 allows the naming of the outputs as well as the lines. This function facilitates the use for the user. Paste on .. : among the options that can be selected, it is possible to paste the settings  ...
  • Page 23: Dialler

    - Associated lines: this parameter defines how many and which outputs will be active with this partition. - Partition name: every partition can be renamed; this function facilitates the use for the end user. - Paste on... : among the selectable options, there is the possibility to copy the settings of a partition onto another (partition name excluded).
  • Page 24 - Activating events (of the channel set in vocal): By this item, you can program the event (or the events) that generate a phone call   Channel 1 Channel type Low battery (ON)   Low battery (OFF) Channel 8 Select lines Lines under alarm No network (ON) Activating events...
  • Page 25   - Various channel settings   Activation delay: a delay from the event to the effective Channel type Channel 1 activation of the channel can be defined from the moment the alarm is released   Channel 8 Repetitions: this parameter Activating events defines the times the associated vocal message is repeated during...
  • Page 26 Telephone number: enter the telephone number or the mobile number that the dialler will dial in the event of an alarm. Activating channels: defines the channels that will activate the call to the associated phone number Name: each number from the Phone Book can be renamed; this function facilitates the use for the end user.
  • Page 27 - Optional telephone functions of the control unit The dialler can be customized with specific optional telephone functions to control the line:   Dialer Voc/Dig. channels Tone control   Phone book Lifting up control Active   NOT active Vocal messages Line control Control unit phone options DTMF confirm.
  • Page 28 PSTN prefix: Set the PSTN prefix by entering a number from 0 to 9. This figure is entered before the phone number to connect the control unit’s dialler to a phone exchange. Reception gain: allows you to select the sensitivity of the telephone, which is 0dB by default.
  • Page 29 Ring number: number of rings that the control unit must hear before allowing remote access. This function is useful if an answering machine device is used in parallel with the dialler of the control unit. Access block: After the MAX. ATTEMPT number has been exceeded, this function allows you to block access to the control unit for a set time (by default 10 minutes).
  • Page 30: Other

      8.1.5 Other The OTHER menu includes various functions which customize the operations of the control unit.   Enter the number Others Max. line alarms     Enter time NO network     Yes/No All messages     Yes / No Call alarm/false code  ...
  • Page 31: Modules

    For each type of family, the first module starts from the address “0” 8.2.1 Keypads The keypad integrated in a plastic case is equipped with a backlighting LCD display and a status LED. Up to 4 remote keypads can be connected to the BUS of the CE2N-416 control unit.   Acquire...
  • Page 32 ATTENTION Do not exceed the maximum limit of 16 inputs managed by the control unit: Example: 4 control unit lines + 8 M8IBUS lines = 12 4 control unit lines + 2 keypad lines + 8 M8IBUS lines = 14 4 control unit lines + 8 M8IBUS lines + 4 M4IBUS lines + 2 keypad lines = 18 - Keypad parameters lift...
  • Page 33 The control cannot be activated in the event that the selected output is already deactivated. • ACTIVATION/ DEACTIVATION OF AN OUTPUT This function allows you to activate or deactivate an output according to the status in which it was previously. •...
  • Page 34: Readers

    - Acquisition of the reader The reader doesn’t have a dip-switch for defining the address number. The acquisition procedure is different from the procedure of the other modules and consists of simply bringing a key to the reader when the control unit is in “Reader acquisition” mode. Activate the “Acquisition”...
  • Page 35: Installer Code

    16 inputs managed by CE2N-416 control unit in the various combination is not exceeded. Acquisition of 2 2-line modules on 2 T8N keypads (dip no. 8 positioned to ON in both...
  • Page 36: Historic Log

    Phone number - Lines being tested The CE2N-416 control unit allows you to test the lines without it activating the alarm outputs and the tone signals from the keypads. Under the test mode, the line is activated according to the programmed modes (for example, a delayed line keeps the input/output time, even when it is being tested).
  • Page 37: Exclusions

    “TOTAL ACTIVATION” will be displayed. - Output function test. The CE2N-416 control unit allows for the testing of all alarm outputs on the card by activating each of them for about 3 seconds.
  • Page 38 Lines Line 1 Exclusions Line 16 Outputs Output 1 Output 7 Dialler Yes / no Channels Channel 1 Channel 32 Phone number Channel 1 Channel 32 Modules keypads keypad 0 line 1 Readers reader 0 reader 3 Line module Linea 8 ATTENTION: if a line is excluded manually or if it is being TESTED and the system is COMPLETELY armed, the CHBUS will display the LED green permanently on (all armed) while the keypad will display the indication of the zone/s excluded and, even if the control unit is compeltely armed,...
  • Page 39: Reset

    9 RESET The procedures can be performed from the keypad by the keys RESET, DEFAULT.   Two procedures are possible: • Keypad reset with a zero address • Restore of factory settings 9.1 RESET THE KEYPAD SERIAL NUMBER WITH A ZERO ADDRESS We would like to specify that all the keypads (such as all the bus devices) are identifi ed by the control unit by means of a serial number in the memory of the devices themselves.
  • Page 40: User Manual

    ATTENTION: if the control unit FIRMWARE must be updated, check the availability of an update from the website www.fracarro.com in the section “Software updating”; the folder contains the instructions to update the control unit. 10 USER MANUAL MASTER code 1111111...
  • Page 41 • Use the arrows to select how many outputs as have been defined before. If the manual outputs of the installer menu were not defined during the programming phase, this option is not valid. • Press the “V” key to turn the symbol besides the output name from “S” in “A” and, therefore, the chosen output is activated.
  • Page 42 Enable installer: With this function, the MASTER user can disable the installer code. This way, the whole installer’s menu and the possibilities to modify the programming will be blocked. Code definition With this function, the MASTER user creates and customizes the new codes that will have different operating functions.
  • Page 43 The system can be managed by the keypad and the electronic key. The electronic keys of the CE2N-416 control unit have the same power of the codes they are associated to. Each key is associated to a user code and it allows the total activation and the partial activation (maximum 4) which are programmed for the user and more keys can be associated to the same code.
  • Page 44 - Acquisition: With this function, the electronic keys are confi gured. • Select the user and confirm with the “V” key • The display shows how many keys were acquired to this user (by default 00) • Three LEDs (red, yellow and green) will start flashing fast in the readers; this shows that the system is ready to acquire the keys •...
  • Page 45 Phone functions Phone book Number 1 Phone number No.: xxxxxxxxx New number Number 16 Name Enter name Digitare Nome 10.5 Historic log The control unit memorizes permanently up to 250 events with the date and time. All the system events are always visible from any keypad, as well as any control unit anomaly and the accesses of the various users, master and installer.
  • Page 46 Lines under Test The CE2N-416 control unit allows you to test the lines without it activating the alarm outputs and the tone signals from the keypads. Under the test mode, the line is activated according to the programmed modes (for example, a delayed line keeps the input/output time, even when it is being tested).
  • Page 47 10.7 Exclusions With the CE2N-416 unit, it is possible to exclude some of the control unit’s functional elements, such as lines or outputs for eliminating possible malfunctioning. The control unit ignores an excluded component; therefore, it is possible to neither receive alarms from an excluded line nor activate the excluded outputs.
  • Page 48 Tel: +39 0423 7361 - Fax: +39 0423 736220 - Società a socio unico. Fracarro France S.A.S. - 7/14 rue du Fossé Blanc Bâtiment C1 - 92622 Gennevilliers Cedex - FRANCE Tel: +33 1 47283400 - Fax: +33 1 47283421...