Air control

4 Air control
A central protective system such as the FCU 500 takes
over air control. It monitors the static air pressure as
well as the air volume required for pre-purge, start-up
and after the furnace has been shut down. The air actu-
ators (BCU with LM..F1 = actuator IC 40, BCU with LM..
F3 = valve) are actuated for this purpose by the capacity
control system of the BCU.
After being enabled by the protective system, the BCU
can start the burners. The capacity is controlled during