Page 2
Follow the “Initial Control/Probe Setup Procedures” in the appendix appropriate for your control. 5. Install the DP-7 and tool holder in the spindle then install the stylus in the DP-7. See Stylus handling and installation procedures on page 4 and perform run-out adjustment as shown on page 5.
Page 14 Grid Digitizing Tips Page 15 Cutting a Copy of Digitized Part, Tips Page 16 Appendix A – CNC10 Centroid Control System Application Page 17 Upgrading from DP-4 and DP-4D Appendix B – CNC11 Centroid Control System Application Page 21...
Exceeding the limits will damage the probe and stylus assembly. The DP-7 is factory tested and adjusted using the stylus components it is shipped with. Specify the required stylus assembly when ordering to minimize the number of adjustments necessary during set up.
The DP-7 works with the Centroid control to minimize pre-travel variation. CNC11 systems are plug-in ready for the DP-7. CNC10 systems require an additional installation kit. See the Centroid appendix for CNC10 installation kit information. DP-7 SPECIFICATIONS: 0.5” ø 1.5”...
STYLUS ASSEMBLY INSTALLATION AND ALIGNMENT PROCEEDURES Important: Read the complete procedure before starting. The DP-7 is factory adjusted for the stylus and stylus extension that are supplied with it. Using other stylus components will probably require some adjustment. When assembling stylus extensions do not twist or apply torque to the carbon fiber or ceramic composite section.
STEP 3: Thread the stylus assembly into the stylus mount boss on the DP-7. Insert a wrench into the hole located closest to stylus mount boss. Place the 3/16" wrench, on the flats of the stylus mount boss. Refer to the pictures below.
Page 9
Run-out Adjustment set-up and effect of Set Screw Movement STEP 2: Rotate the spindle by hand (without touching the probe) so that the probe spins through a full 360 degrees and watch the dial indicator to locate the high and low run-out rotation positions of the stylus.
Adjust the stylus tip run-out last. WHEN TO CHECK ANGULAR ALIGNMENT: The DP-7 when shipped with a long stylus assembly is aligned for that assembly at the factory. When replacing stylus assemblies with off the shelf parts it is likely adjustment will be needed.
The angular alignment procedure has a high degree of difficulty. Read this entire section and be certain adjustment is necessary before attempting it. Consider having Centroid (TM) perform this adjustment, test the probe and install any up-grades that may be applicable to continue reliable performance.
STEP 2: Plug the retractile cord into the DP-7 probe and into the digitizing port on the control. The cord ends are keyed to prevent incorrect connection. At the probe end line-up the red dot with the red painted slot on the probe connector, push the plug in until it clicks.
Calibration complete. MAINTENANCE AND CARE Do not submerge or expose the DP-7 to liquids. Wipe off any liquids immediately to prevent internal contamination or degradation of the rubber seal and indicator lens. The probe body is stainless steel and should only be wiped clean with compatible cleaners.
SHIPPING INSTURCTIONS If the probe must be shipped it should be removed from the tool holder and the stylus assembly must be removed from the probe. Use the original plastic shipping tube and insert the probe in the tube with the stylus mount boss located inside the foam ring in the tube. The foam should prevent the stylus mount boss from touching the end of the plastic tube if jarred during shipping.
COMMON CABLES: The photo below shows the DP-7 connected to the primary cable assemblies common to all installations. Note the bulkhead connector to provide physical support for the coil cord. No additional adapters are needed for new Centroid (TM) CNC11 systems. See the appropriate appendix in the this manual for additional required adapters, connection diagrams and parameter settings for specific applications.
Good repeatability is not a substitute for low PTV. The DP-7 was developed specifically for 3D digitizing accuracy with long stylus assemblies. Determine the acceptable digitizing error for the project, the probe PTV (3D) must be less than the acceptable error.
Conversely if you scale the part by ½ then the cutter diameter needed would be 0.125”. You can also import your digitized data into an online CAM program on your Centroid control or export it to an offline CAM system.
6) RTK3 DIGITIZE CABLE with splice connectors 7) DP-7 PROBE Photo 1. shows the general interconnection of the components for the DP-7 up grade. The splice connections are not made until all the cables have been routed. The DSP conduit cable must be pulled through the conduit to the console where the CPU10B is located.
Page 21
14 will flash alternately red green then stay red. Also check for a flashing red LED on the CPU10B daughter card. When the DP-7 is first connected it will flash its outputs and LED indicator light as a diagnostic tool. The corresponding inputs on the control should change (flash) as well.
Page 22
UPGRADING FROM DP-4D: To upgrade from DP-4D the following hardware items are required: 1) Swap out CPU10B motion control card with daughter card 2) Software updates UPDATING CNC10 SOFTWARE TO RUN THE DP-7 2.70 software update • 2.71rev46 software update •...
Page 23
Util, F5-File ops, highlight your USB device and press enter, highlight DP7 folder and press enter. Put a star beside the manualprobing_dp7.nc file and press F3- Import/Export. Then highlight [c:\] press enter, highlight [cnc10], highlight [ncfiles], and then press F10-Accept. Last Modified 2014-09-16 04:12:44 AM Page 20 of 21 C:\Users\Keith\AppData\Local\Temp\7zO0E521723\DP7body20140916.odt...
50771 will turn on solid green and 50769 and 50770 will flash alternately red green then stay red. 50770 is a special DP-7 hard wired input. Only the last three digits 769, 770 and 771 are displayed on the diagnostic screen. Use the F12 and F11 keys to scroll through the diagnostic screens to find the inputs.