Rise Time
Settling Time
Equivalent Measurement Bandwidth The eective
Trigger Level
Trigger Width
Minimum Time Delay
Maximum Time Display
10% to 90% of the test and reference channel
detectors: 300 nanoseconds.
The time required for a ratioed,
high-leveled measurement to reach within 0.1 dB of its nal
value when the system is in pulse prole mode.
post-detection bandwidth of the test and reference detectors in
the HP 8510.
TTL.
The minimum pulse width to be applied to
the rear panel input of the HP 8510 for the HP 8510 to make a
measurement. (External trigger mode: 100 nanoseconds).
The minimum time span of the x-axis
of the HP 8510 display in pulse prole mode: 5 nanoseconds.
The maximum time span of the
x-axis of the HP 8510 display in pulse prole mode: 40
milliseconds.