Power IC, Transistor or Devices Removal/Replacement
1. Heat and remove all solders from the device leads.
2. Remove the heatsink mounting screw (if applicable).
3. Carefully remove the device from the circuit board.
4. Insert new device in circuit board.
5. Solder each device lead and then clip off excess lead.
6. Replace heatsink.
Diode Removal/Replacement
1. Remove defective diode by clipping its leads as close as possible to diode body.
2. Bend the two remaining leads perpendicularly to the circuit board.
3. Observing diode polarity, wrap each lead out of the new diode around the corresponding lead on the
circuit board.
4. Securely crimp each connection and solder it.
5. Inspect the solder joints of the two "original" leads on the circuit board copper side. If they are not
shiny, reheat them and apply additional solder if necessary.

TECHNICAL INFORMATION

Model Names
CDT Size
Diagonal visible image area
Dot Pitch
Synchronization
Plug and Play
Power Saving
Power Source
Power Consumption
Dimension(mm)
(set with stand)
Weight-unpacked(lbs/Kg)
Operating Temperature
All manuals and user guides at all-guides.com
902D
19-inch
18-inch
0.26 mm
Horizontal 30 - 95 KHz
Vertical
50 - 160 Hz
DDC1/2B/CI
EPA, VESA DPMS, Nutek Compliant
100-240 Vac, 50/60Hz (Free Voltage)
120 W
466(W)
475.5(H)
464.5(D)
51.8/23.5
10 ~ 40°C /50 ~ 104°F