2 Channel RS485-Sensor-Interface SI-RS485
Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131
090325c_SI-RS485
73553 Alfdorf Phone. +49 7172 93730-0, Fax +49 7172 93730-22
Technical changes, errors and misprints excepted.
1/13
info@lorenz-messtechnik.de,
www.lorenz-messtechnik.de

Advertisement

Table of Contents
loading

Summary of Contents for Lorenz SI-RS485

  • Page 1 Amplifiers 2 Channel RS485-Sensor-Interface SI-RS485 Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090325c_SI-RS485 73553 Alfdorf Phone. +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 1/13 info@lorenz-messtechnik.de, www.lorenz-messtechnik.de...
  • Page 2: Table Of Contents

    Pin Assignment for Active Current Sensors with mA Signal Connection Assignment for the RS485-Interface Other Application Examples Multi-Component Sensor M-2354 Force and Torque (strain gauge / strain gauge) Displacement Sensor Potentiometric (supplied from the SI-RS485) Debugging Technical Data Options Accessories...
  • Page 3: Imprint / Copyright

    These operating instructions do not constitute an agreed quality agreement or durability guarantee within the meaning of § 443 BGB (German Civil Code). Technical changes, errors and misprints excepted. No part of this publication may be reprinted without the written permission of Lorenz Messtechnik GmbH, Alfdorf. Important Notes / Keeping Before installing and commissioning the device, these operating instructions, and in particular the corresponding safety instructions, must be read.
  • Page 4 The devices do not contain any parts that require or can be serviced by the user. Repairs may only be carried out by Lorenz Messtechnik GmbH. If it can be assumed that safe operation of the device is no longer possible, it must be put out of operation immediately and secured against unintentional operation.
  • Page 5: Intended Use

    Intended Use Devices from Lorenz Messtechnik GmbH are to be used exclusively for measuring tasks and the di- rectly associated control tasks. Any use beyond this is considered to be improper. The valid legal and safety regulations must be observed during measurement. The instrument is not a safety component in the sense of its intended use and it is transported and stored properly.
  • Page 6: Health Protection And Safety

    The current supply occurs via a separate power supply which is included in delivery. Required output voltage: 12 ... 30V Required power supply: 600 mA The SI-RS485 is suitable for the connection and simultaneous value acquisition of two sensors. De- pending on the SI-RS485 model, respectively four different types of sensor signals can be captured (for specifications see data sheet): Strain gauge signals: ±3 mV/V (corresponds ±30000 digits)
  • Page 7: Safe And Correct Use

    Technical Details 5.1 Configuration of the Connections There is no maintainable connection inside the SI-RS485 housing. The connection of the power sup- ply unit occurs on the side of the housing. The sensors and the digital interface can be connected through sockets as well.
  • Page 8: Changing Via Lcv-Usb-Vs

    Relating to signal input (internally 0V / GND) Control signal If available in sensor Shield Do not connect shield with sensor housing Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090325c_SI-RS485 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 8/13 info@lorenz-messtechnik.de,...
  • Page 9: Pin Assignment For Active Current Sensors With Ma Signal

    Multi-Component Sensor M-2354 Force and Torque (strain gauge / strain gauge) The multi-component sensor M-2354 is directly connec- ted to the SI-RS485/DMS/DMS with both outputs. The system allows simultaneous recording of force-torque- courses which chronologically refer to each other. Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131...
  • Page 10: Displacement Sensor Potentiometric (Supplied From The Si-Rs485)

    Displacement Sensor Potentiometric (supplied from the SI-RS485) 5V reference controller A SI-RS485 with minimum U5-input is suitable. The accuracy of the displacement measurement is depending on the quality of the reference vol- Signal+ tage. With this set-up, arbitrary measuring variables, depending on displacement measurements, can be recorded and referred to each other.
  • Page 11: Technical Data

    125 x 80 x 57 mm Level of protection IP40 Weight 0.5 kg Mains adapter included in scope of delivery at first order Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090325c_SI-RS485 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 11/13 info@lorenz-messtechnik.de, www.lorenz-messtechnik.de...
  • Page 12: Options

    - Calibration at 225 Hz: Normal BN100A, if so display above HBM DMP40 Equipment disposal The device must be disposed of in accordance with the applicable legal regulations - see also our „General Terms and Conditions of Delivery and Sale“ at www.lorenz-messtechnik.de Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090325c_SI-RS485 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted.
  • Page 13: Reference Information

    Document number 080997, data sheet (German 080996) • Document number 090367 “Operation Manual for Configuration an Evaluation Software VS3” (German 090366) • Document number 090110 Lorenz protocol “A flexible command set for digital sensors and interfaces“ Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090325c_SI-RS485 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 13/13 info@lorenz-messtechnik.de, www.lorenz-messtechnik.de...