Turn The Heater On Or Off; Temperature Units; Setting The Thermostat - NOMA 043-5116-4 Instruction Manual

Digital baseboard heater
Table of Contents

Advertisement

6
model no. 043-5116-4 | contact us: 1-866-827-4985

TURN THE HEATER ON OR OFF

Upon plugging in the heater, the Power
Indicator Light will be illuminated and the unit
will be in its standby state. In this state, "- -" is
shown on the display and indicates that the
unit is on but not heating.
Pressing the ON/OFF button once will
select the Low Heat (750W) setting,
indicated by the illumination of the Low
Heat Indicator Light.
Pressing the ON/OFF button a second time
will select the High Heat (1500W) setting,
indicated by the illumination of the High
Heat Indicator Light.
Pressing the ON/OFF button a third time
will return the heater to the standby state.
Make sure the heater is in the standby state
before unplugging. The heater should be
unplugged when not in use.
NOTE: During the heater's initial use, you
may experience a slight odour or smoking.
This is the result of the heating element
lubrication "burning off". This is normal and
will go away after a few minutes of use.
NOTE: Heater will function in the Low or
High heat setting independently of the
thermostat, when the thermostat is set to
"00C" or "00F".
NOTE: The temperature value displayed in
both heat settings is the current ambient
temperature.

TEMPERATURE UNITS

To switch between Celsius and Fahrenheit
units, press the MODE button once. The
digital display will blink 3 times and then
automatically switch. Temperature will reset
to the default setting when units are changed.

SETTING THE THERMOSTAT

When the heater is in the heat setting
(either Low or High), press the UP/DOWN
button once to select the thermostat
option. This is indicated by the illumination
of the Temperature Indicator Light and by
a flashing "00C" on the display (or "00F",
depending on the selected units). At this
time, press the UP/DOWN buttons to raise
or lower the temperature set point.
Once the desired temperature is reached,
press the MODE button once to select
the Timer option or twice to exit both
options – this will return the display to the
ambient temperature. Alternatively, the
unit will automatically save and exit after 15
seconds of inactivity, returning the display
to the ambient temperature. After exiting,
the Temperature Indicator Light will remain
illuminated to show that the thermostat
option is active.
NOTE: When the ambient air temperature is
equal to or below the thermostat set point,
the heater will automatically turn on. If the
ambient air temperature is greater than the
thermostat set point, the heater will turn off
OR