AAT KaDe KDH-KS2024-IP Installation Manual

AAT KaDe KDH-KS2024-IP Installation Manual

Standard controller

Advertisement

Installation Manual
STANDARD CONTROLLER
KDH-KS2024-IP
VERSION 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KaDe KDH-KS2024-IP and is the answer not in the manual?

Questions and answers

Summary of Contents for AAT KaDe KDH-KS2024-IP

  • Page 1 Installation Manual STANDARD CONTROLLER KDH-KS2024-IP VERSION 1.0...
  • Page 2: Table Of Contents

    6. Power supply, lock, Ethernet, door sensor and I/O module connection 7. APSAAT4 power supply for KDH-KS20XX series controllers ………….….. 8. Controller module installation and connections in housing ………………… 9. Adding cards to controller memory without software ………………………… 11 All rights reserved. © AAT HOLDING S.A.
  • Page 3: Introduction

    Standard controller, 1 door - two way, 2 doors - one way, 2 readers ports, RS485 port KDH-KS2012-RS for communication and RS485 port for extension module, buffer for 20 000 cards, 50 000 events, 20 000 alarms All rights reserved. © AAT HOLDING S.A.
  • Page 4: Kdh-Ks2024-Ip Controller Technical Data

    - access levels - schedules - holidays (single or multiple-day periods) 80 x 64 days Identification mode Card, PIN, Card or PIN, Card + PIN Alarm dismiss Synchronize with input state or delay All rights reserved. © AAT HOLDING S.A.
  • Page 5: General Guidelines For Controller Installation

    Controller (4×1.0) Door contact > Controller 2-core cable 150m (2×0.5) Exit button > Controller 2-core cable 150m (2×0.5) Detector > Controller input 2-core cable 150m (2×0.5) Mains power supply 230VAC 3-core cable (3×1.5) All rights reserved. © AAT HOLDING S.A.
  • Page 6: Kdh-Ks2024-Ip Controller Module

    Relay output Alarm input 3 Alarm input 4 Power supply 12 VDC Controller operating indicator Relay X switch indicator Card reading indicator +12 VDC power supply indicator Two door control mode indicator 4 DOOR All rights reserved. © AAT HOLDING S.A.
  • Page 7: Reader, Exit Button And Sensor Connection

    Indicator of communication with reader: when user presents card to the reader, LED (RD_OK) on the controller module lights up—only, when connection with reader is correct and controller port works correctly. Otherwise, LED will not light up. All rights reserved. © AAT HOLDING S.A.
  • Page 8: Power Supply, Lock, Ethernet, Door Sensor And I/O Module Connection

    Notes: Address dipswitches should be left at default settings (all ON). Present firmware of 2000 series controllers supports only one module. In future it will be possible to connect more modules, with different addresses, to one controller. All rights reserved. © AAT HOLDING S.A.
  • Page 9: Apsaat4 Power Supply For Kdh-Ks20Xx Series Controllers

    I/O module, tamper switch and battery. Detailed information about all parameters and terminals in APSAAT4 power supply are specified in the operating manual of the power supply on the website: http://www.aat.pl/pl/products/2930/APSAAT4 All rights reserved. © AAT HOLDING S.A.
  • Page 10: Controller Module Installation And Connections In Housing

    Housing can be closed with two screws, fas- tened on the right . Opening of the enclosure is monitored by tamper switch, which gen- erates alarm, if it’s not temporarily disabled by administrator, for service purposes. All rights reserved. © AAT HOLDING S.A.
  • Page 11: Adding Cards To Controller Memory Without Software

    Read the programming card in the reader three times. Entering to program- ming mode is indicated by LED on the reader flashing green. After 4 seconds read programming card again. All cards are deleted and reader will leave the programming mode. All rights reserved. © AAT HOLDING S.A.

Table of Contents

Save PDF