Order No.: 341 298 1. Introduction Thank you for choosing a spega product. This product has been designed and optimized for use in room automation. To familiarize yourself with the handling and functionality of the system, we would ask you to read this manual carefully. It contains information about the operation, assembly and parameterization of the system.
Electrical devices must be assembled and installed by trained personnel only. Operation of the device is determined by the application software. Only software which has been approved by spega should be used for this device. The system integrator should ensure that the software and relevant parameterization correspond with the wiring and intended use of the device.
Manual for ombra BST LON slat angle automat Order No.: 341 298 2. Product description The device ombra BST is a LON automat for sun position dependent tracking of blind slats. A maximum of 15 facade segments can be - depending...
Manual for ombra BST LON slat angle automat Order No.: 341 298 2.1. Technical Data Power supply Operating voltage 24V DC / 15...27V DC Power max 70mA (1680mW) Network Network type TP/FT-10 (78kbps) Transceivertype Connections Network / Power supply 4-pin plug-in terminal connection for Ø 0,6 - 1,0mm (sol.), four bus lines can be connected for each pin.
Page 8
Manual for ombra BST LON slat angle automat Order No.: 341 298 Ambient conditions Operating temperature 0°C ... +50°C Storage temperature -25°C … +55°C Transport temperature -25°C ... +70°C Relative humidity 5% … 93% (w/o condensation) Height of use up to 2000 m above sea level...
The device specifications must be observed. The device function is determined by the application program. Only programs which have been released by spega for this device may be loaded. The system installer must ensure that the application program and the associated parameterization correspond to the circuitry and the intended use of the device.
Page 10
Manual for ombra BST LON slat angle automat Order No.: 341 298 Version 1.00 Page 10 / 34 08.09.2020...
Manual for ombra BST LON slat angle automat Order No.: 341 298 2.3. Installation 2.4. Operation Commissioning: For commissioning, a service button and a service LED are mounted on the front side (under the aluminium front). The Neuron-ID is sent by pressing the button.
Device Application ombra BST SC341298EC_14 3.1. Application data In the spega device template manager you can select the required application. In this way, the required application files, resource files and plug- ins are transferred for the corresponding project. Application SC341298EC_14...
Order No.: 341 298 4. Set up a device To use an ombra BST in your project, first install the e.control plug-in setup from the CD or from the internet. The setup includes the application files, LNS plug-ins and configuration software as well as the manual. More detailed information on the installation and use of the plug-ins can be found in the chapter "The spega e.control Plug-ins".
LON slat angle automat Order No.: 341 298 5. Device functions With the device ombra BST the slat tracking and the shading correction can be realized. 5.1. Slat tracking Slat tracking cyclically adjusts the position of blinds to the current position of the sun.
Page 15
Manual for ombra BST LON slat angle automat Order No.: 341 298 to combine glare control and light directing strategy, this is also possible. However, this requires special blinds, which have mirrored light-directing louvers in the area of the skylights and conventional louvers in the window area.
Page 16
Manual for ombra BST LON slat angle automat Order No.: 341 298 A further restriction for the condition "sun shines on facade" is made possible by the adjustability (via plug-in) of so-called dead angles (for azimuth and elevation). It serves to optimize the system. If, for example, an adjacent...
Manual for ombra BST LON slat angle automat Order No.: 341 298 and sun protection systems with an 80° angle range, this results in a positioning accuracy of 2.5°. Therefore, if an activation takes place after the calculation of the new slat angle, the angle change of 10°...
The software of the device provides a total of 23 objects (functional units). These include 15 suntracking controller objects, whose output variables can be used to communicate the calculated slat angle to the spega blind actuators for up to 15 different building facades. Version 1.00 Page 18 / 34...
Page 19
Manual for ombra BST LON slat angle automat Order No.: 341 298 The important settings can now be made in the device plug-in. Version 1.00 Page 19 / 34 08.09.2020...
Page 20
Manual for ombra BST LON slat angle automat Order No.: 341 298 In addition to building data such as time zone or geographical position, the data of the individual facades are also specified here. The individual facades can then be assigned to the individual SuntrackingCtr objects.
Page 21
Manual for ombra BST LON slat angle automat Order No.: 341 298 The ombra BST now continuously calculates the optimum slat angle based entered parameters and makes this available to the LON network via the output network variables. Version 1.00 Page 21 / 34 08.09.2020...
Manual for ombra BST LON slat angle automat Order No.: 341 298 6.2. Shading correction The plug-in for configuring the Shading correction is started here. Version 1.00 Page 22 / 34 08.09.2020...
Page 23
Manual for ombra BST LON slat angle automat Order No.: 341 298 All objects within the project which represent a spega blind actuator channel are automatically displayed here. Version 1.00 Page 23 / 34 08.09.2020...
Page 24
Manual for ombra BST LON slat angle automat Order No.: 341 298 Next, a "New facade" is configured. Version 1.00 Page 24 / 34 08.09.2020...
Page 25
Manual for ombra BST LON slat angle automat Order No.: 341 298 A facade view with the individual windows/axes and floors is now created in the right window according to the configuration. In the lower area, the appropriate settings can be made for each window.
Page 26
Manual for ombra BST LON slat angle automat Order No.: 341 298 The individual blind objects are now assigned to the corresponding windows via "Drag and Drop". Version 1.00 Page 26 / 34 08.09.2020...
Page 27
About the functionality of shading correction The configuration which you make in the plug-in is stored directly in a parameter (UCPTShadowingObjects) which is available in every spega e.control blind actuator object. On the basis of this information, each individual object "knows" at all times whether it is currently in shadow or not and thus also whether it must react to the automatic commands of the slat tracking system at all or not.
Manual for ombra BST LON slat angle automat Order No.: 341 298 7. Room automation functions (bindings) 7.1. Slat tracking To realize a slat tracking system, the slat tracking object (facade) of the slat angle automat is connected to the sun protection objects of the assigned facade.
Page 29
Manual for ombra BST LON slat angle automat Order No.: 341 298 The number of sun protection objects per facade is not limited. When using different sun protection functions, the priority control should be used to give priority to the functions.
Manual for ombra BST LON slat angle automat Order No.: 341 298 7.2. Shading correction To realize the annual shading, the sun position determination of the slat angle automat is connected to the sun position input of the node on which the sun protection actuators are located.
Page 31
Manual for ombra BST LON slat angle automat Order No.: 341 298 In addition, the shading data for the individual sun protection areas must be parameterized via the annual shading plug-in of the automatic slat angle control. This plug-in ensures that each sun protection actuator involved receives its relevant data for shading, taking into account the current position of the sun to determine whether it is shaded.
Manual for ombra BST LON slat angle automat Order No.: 341 298 8. Glossary alternating current Alias entry address entry for a member of a group binding in the sending node amplitude shift keying Bluetooth industry standard for wireless radio networking over short...
Page 33
Manual for ombra BST LON slat angle automat Order No.: 341 298 Short address individual address for identification of DALI devices light emitting diode LonWorks network services LON™ local operating network LonMark™ international organization with the intention to advance and bring forward the LON technology LonWorks™...
Page 34
Manual for ombra BST LON slat angle automat Order No.: 341 298 Transmitter ID individual, unique 32-bit transmitter identification for wireless transmitters, based on EnOcean technology UCPT user configuration property type UNVT user network variable type ‚VDE Verband der Elektrotechnik, Elektronik und Informationstechnik e.V.‘...
Need help?
Do you have a question about the ombra BST and is the answer not in the manual?