ALTRONIC RESEARCH, INC. P.O. BOX 249 YELLVILLE, ARKANSAS 72687, U.S.A. DECLARATION OF CONFORMITY The Omegaline RF Coaxial Load Model 6600 Series conforms to the following standards: Low-Voltage Directive (2014/35/EU) Electromagnetic Compatibility Directive (2014/30/EU) Machinery Directive (2009/127/EC) Restriction of Hazardous Substances Directive (EU)2015/863...
3-8 Connections ................13 3-9 Adjustments ................13 3-10 Preparation for Reshipment ............13 IV. Theory of Operation 4-1 General ..................14 Maintenance 5-1 Cleaning ..................14 5-2 RF Circuit ................... 14 5-3 Resistor Replacement ............15-17 6600/Rev/Mar.2021 Page 5 Altronic Research Inc.
Page 6
SECTION PAGE VI. Diagrams 6-1 Outline and Dimensions ............18-21 6-2 Parts List ..................22 VII. Specifications ................... 23 VIII. Preservation and Corrosion Prevention Techniques ......24-28 6600/Rev/Mar.2021 Page 6 Altronic Research Inc.
IN THE EVENT OF OVERHEAT, BUT THE INTERLOCK MUST BE PROPERLY CONNECTED TO THE RF SOURCE FOR THIS FUNCTION TO OPERATE. NEVER OPERATE WITH INTERLOCK BYPASSED OR MALFUNCTIONING. TO DO SO WILL VOID THE WARRANTY. 6600/Rev/Mar.2021 Page 7 Altronic Research Inc.
Page 8
Do not apply more than rated power to unit. Damage will occur if large overloads are applied. CAUTION When using any cleaning solvents or solutions, assure that there is adequate ventilation to protect personnel from breathing any irritable or possibly toxic fumes. 6600/Rev/Mar.2021 Page 8 Altronic Research Inc.
Load is correctly connected to the RF source and the transmitter alarm, operate transmitter as desired. Units purchased with fans may be operated after ascertaining that the load is connected to the correct power supply with a disconnect, connect the transmitter interlock 6600/Rev/Mar.2021 Page 9 Altronic Research Inc.
The proper procedure to lock out and mark controls prior to allowing or commencing maintenance on the equipment; The proper procedure to obtain clearance to remove lockouts and out-of-service marks and return the equipment to normal service. 6600/Rev/Mar.2021 Page 10 Altronic Research Inc.
While inspecting RF connector, measure DC resistance of the unit by reading from the center conductor to the outer conductor. Compare this reading to that on the specification sheet at the end of this manual. Reading should be ± 1 ohm. If not, consult factory. 6600/Rev/Mar.2021 Page 11 Altronic Research Inc.
• Test for proper fan operation by jumping the terminals of either thermal switch that is wired in the fan circuit. They have a yellow dot on them. • Place the roof back on the load. 6600/Rev/Mar.2021 Page 12 Altronic Research Inc.
3-10. Preparation for Reshipment. No special measures are required to prepare the Model 6600 Series Coaxial Load for reshipment. Care must be taken to protect the RF connector and to immobilize the swivel flange. Packaging should provide protection against abrasion and impact. 6600/Rev/Mar.2021 Page 13 Altronic Research Inc.
5-2. RF Circuit. The RF Load Resistor does not require any periodic maintenance and the only repairs possible are the replacement of parts in the connector, quickstep or support portions of the resistor assembly or the replacement of resistors. 6600/Rev/Mar.2021 Page 14 Altronic Research Inc.
Fig. 3 Fig. 4 Remove the 8-32 X ½” screws from the tower panel as shown in Figure 5. Fig. 5 6600/Rev/Mar.2021 Page 15 Altronic Research Inc.
Page 16
Removing the resistors without first loosening these screws may cause the resistors to break or crack. The resistors are hard, brittle ceramic material. Avoid impact and excessive force when installing or removing them. Fig. 8 6600/Rev/Mar.2021 Page 16 Altronic Research Inc.
Page 17
¼ - 20 X 2” hex head bolts shown Figure then the bolts shown Figure 11. Fig. 11 Assembly is done by reversing the process described in this section. 6600/Rev/Mar.2021 Page 17 Altronic Research Inc.
6-2 REPLACEMENT PARTS LIST (CONSULT FACTORY) CALL 870-449-4093 When consulting the factory for replacement parts please have the model and the serial number of loads requiring service. 6600/Rev/Mar.2021 Page 22 Altronic Research Inc.
Frequency Range --------------------------------------------------------- DC to 110 MHz Cooling Method ----------------------------------------------------------- Static air Ambient Temperature --------------------------------------------------- -30°C to 40°C Finish --------------------------------------------------------------- durable acrylic finish Serial No._______Frequency____________Resistance_________ dBA @ 3’ _0__ Model________________________________Inspected by___________Date________________ CRAFTED WITH PRIDE IN ARKANSAS, U.S.A. 6600/Rev/Mar.2021 Page 23 Altronic Research Inc.
Y E L L V I L L E AR 7 2 6 8 7 - 0 2 4 9 U S A Altronic Research, Inc. Preservation and Corrosion Prevention Techniques Omegaline 6600 Series RF Loads Improving product life in hostile environments 6600/Rev/Mar.2021 Page 24...
Page 25
RF loads in hostile environments. 2. Applicability These instructions are applicable to equipment designed and manufactured by Altronic Research Inc. for use by the broadcast and scientific industries. These instructions do not apply to equipment manufactured by others which may, from time-to-time, be supplied as accessory equipment for use with Altronic Research Inc.
Page 26
Use MIL-C-10578D Compound, Corrosion Removing and Metal Conditioning, Type IV in accordance with the included instructions. Available from Altronic Research, Inc. [Part Nr. 000-77000-CCR].
Page 27
The solution is to remove the resistors and return them to the factory for reprocessing. If the condition is discovered early in the failure, there is every likelihood that all of the resistors can be reused. If the failure is allowed to progress, resistor replacement becomes necessary. 6600/Rev/Mar.2021 Page 27 Altronic Research Inc.
Page 28
The technicians at the factory are always available for advice and assistance. You may contact them via FAX, e-mail or telephone. Our numbers are: FAX 001-870-449-6000 E-mail customerservice@altronic.com Telephone: US WATS = 800-482-5623 Direct dial: 001-870-449-4093 6600/Rev/Mar.2021 Page 28 Altronic Research Inc.