  • Page 1 Robo-Drain Installation & Operation Manual 716/683.0435 AIR SYSTEM PRODUCTS Model RD11-VAC ASPSalesTeam@airsyspro.com 51 Beach Ave. www.airsyspro.com Lancaster, NY 14086 Zero-Loss Condensate Drain Making the World Safer, Healthier & More Productive...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS GENERAL INFORMATION ..........................3 SAFETY ............................... 3 WARRANTY .............................. 3 INSTALLATION ............................4 PRODUCT INFORMATION INSTALLATION ..........................4 POST-INSTALLATION CHECK ......................4 TROUBLESHOOTING ........................4 OPTIONS ............................4 INSTALLATION CONSIDERATIONS ....................5 RECEIVER ............................5 FILTER AND AFTERCOOLER SEPARATOR ................. 5 REFRIGERATED DRYER .......................
  • Page 3: General Information

    GENERAL INFORMATION SAFETY Locate, read, understand, and follow all Danger, Warning, Caution, and Operating Instructions on the product and in all manuals. Failure to comply with safety precautions described in the manuals supplied with the product this manual or any of the labels and tags attached to the product may result in death, serious injury or property damage.
  • Page 4: Installation

    3. Inspect for any air or condensate leaks. Correct as The Robo-Vac is designed for trouble-free operation. When installed and operated properly, the Robo-Vac will provide necessary. years of reliable service collecting and discharging condensate, along with pipe scale and other contaminants typically found in vacuum systems.
  • Page 5: Installation Considerations

    GENERAL INSTALLATION CONSIDERATIONS For the condensate to properly enter the drain reservoir, the DWG 1. condensate line to the drain must always be installed below the bottom of the vessel to be drained. It is equally important to provide a means for the air that is contained in the reservoir to escape (balance line) as the condensate enters the reservoir.
  • Page 6: General Specifications

    GENERAL SPECIFICATIONS Inlets: One (1) 3/4" NPT Outlet: 1/2" NPT Power: Clean, Dry Air: 60 - 130 PSI (Standard Design) 40 – 130 PSI (Low Control Pressure Design Option) Operating Pressure: 26” Hg to 90 PSI High Pressure and Stainless Steel Designs Available Operating Temperature: 32°...
  • Page 9: Parts List

    SPARE PARTS (Refer to RD11-VAC-NPT-EXP drawing on previous page.) Item No. Qty. Part No. Description RDP-H2-KIT Control Head Assembly RDP-H1-KIT Inlet Head Assembly SSP-COCYL Translucent Cylinder ED-G Cylinder O-Rings RDP-VHG2, RDP-VHG3 Trigger Assembly O-Rings RDP-FILTER Control Air Inlet Filter 5a,b 4/16 RDP-BOLT-KIT Bolt/Nut Kit...