Filtration Group Air System Products Robo-Drain RD750 Installation & Operation Manual

Filtration Group Air System Products Robo-Drain RD750 Installation & Operation Manual

Advertisement

Quick Links

Installation & Operation Manual
AIR SYSTEM PRODUCTS
51 Beach Ave.
Lancaster, NY 14086
Making the World Safer, Healthier & More Productive
Robo-Drain
716/683.0435
ASPSalesTeam@airsyspro.com
www.airsyspro.com
Model RD750
Zero-Loss Condensate Drain

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Air System Products Robo-Drain RD750 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Filtration Group Air System Products Robo-Drain RD750

  • Page 1 Robo-Drain Installation & Operation Manual 716/683.0435 AIR SYSTEM PRODUCTS Model RD750 ASPSalesTeam@airsyspro.com 51 Beach Ave. www.airsyspro.com Lancaster, NY 14086 Zero-Loss Condensate Drain Making the World Safer, Healthier & More Productive...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS GENERAL INFORMATION ..........................3 SAFETY ............................... 3 WARRANTY .............................. 3 INSTALLATION ............................4 PRODUCT INFORMATION INSTALLATION ..........................4 POST-INSTALLATION CHECK ......................4 TROUBLESHOOTING ........................4 OPTIONS ............................4 INSTALLATION CONSIDERATIONS ....................5 RECEIVER ............................5 FILTER AND AFTERCOOLER SEPARATOR ................. 5 REFRIGERATED DRYER .......................
  • Page 3: General Information

    GENERAL INFORMATION SAFETY Locate, read, understand and follow all Danger, Warning, Caution, and Operating Instructions on the product and in all Manuals. Failure to comply with safety precautions described in the manuals supplied with the product this manual or any of the labels and tags attached to the product may result in death, serious injury or property damage.
  • Page 4: Installation

    The Robo-Drain is designed for trouble-free operation. CHECKING THE OPERATION When installed and operated properly, the Robo-Drain will After installation is complete and the drain is in service, a provide years of reliable service collecting and discharging check should be made that the drain is functioning properly. condensate, along with pipe scale and other contaminants 1.
  • Page 5: Installation Considerations

    INSTALLATION CONSIDERATIONS For the condensate to properly enter the drain reservoir, the DWG 1. condensate line to the drain must always be installed below the bottom of the vessel to be drained. It is equally important to provide a means for the air that is contained in the reservoir to escape (vent) as the condensate enters the reservoir.
  • Page 6: General Specifications

    GENERAL SPECIFICATIONS Inlets: Two (2) 3/4" NPT (BSPP Optional) Outlet: 1/2" NPT (BSPP Optional) Power: Clean, Dry Air: 60 - 130 PSI (Standard Design) 40 - 130 PSI (Low Control Pressure Design Option) Operating Pressure: 0 to 750 PSIG (0-51 bar) Vacuum and High Pressure Designs Available Operating Temperature: 32°...
  • Page 9: Parts List

    SPARE PARTS (Refer to RD11-T-NPT-EXP drawing on previous page.) Item No. Qty. Part No. Description RDP-H2-KIT Control Head Assembly RDP-H1-KIT Inlet Head Assembly SSP-COCYL Translucent Cylinder ED-G Cylinder O-Rings RDP-VHG2, RDP-VHG3 Trigger Assembly O-Rings RDP-FILTER Control Air Inlet Filter 5a,b 4/16 RDP-BOLT-KIT Bolt/Nut Kit...
  • Page 10 AIR SYSTEM PRODUCTS 51 Beach Avenue Lancaster NY USA P: +1 716-683-0435 www.airsyspro.com All design specifications subject to change without notice © 2020 ASP-S-RD-4750-102220...

Table of Contents