Frigidaire GLFU1467FW0 Service Data Sheet page 2

Automatic defrost upright freezer

Advertisement

IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
should not attempt to make
repairs due to the possibility of
electrical
shock.
Disconnect
power cord before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three
inches of clearance must be provided on all sides of the freezer for air
circulation.
The freezer should be positioned on a solid floor, and the front of the
cabinet should be raised just enough to provide easy door closure when
open about half way.
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
4.0°F cut in, -10.0°F cut-out @ number 1 setting.
DEFROST CONTROL
An automatic 30 minute defrosting period is initiated after every 12 hours of
compressor running time. During the defrosting period a thermostat will
switch the defrost heater off after the frost on the evaporator has melted. The
defrost thermostat closes at 10°F and opens at 50°F.
PERFORMANCE (Control at number 1 setting)
Room Ambient
Freezer Compartment Temperature
Percent Running Time
*Wattage Range (Last
1
of cycle)
3
Suction Pressure (Cut-in, cut-out), PSIG
High Side Pressure (Last
of cycle), PSIG
1
3
Specifications subject to change without notice.
*For complete performance data by model refer to service manual.
AVISO IMPORTANTE DE SEGURIDAD
La información aquí provista está destinada
a ayudar al personal calificado de
reparación solamente. Las personas no
especializadas en esta materia no deben
intentar hacer reparaciones debido a la
posibilidad
de
choque
eléctrico.
Desconecte el cordón eléctrico antes del
mantenimiento.
INSTALACION
Este producto está diseñado para "instalación autónoma solamente" y se
debe proveer tres pulgadas de holgura en todos los lados del congelador
para circulación del aire.
El congelador debe ser instalado sobre suelo firme y la parte delantera del
gabinete debe estar levantada solamente lo suficiente como para permitir
el cierre fácil de la puerta cuando se abre hasta la mitad.
PARA LAS ESPECIFICACIONES ELECTRICAS Y CARGA DEL
REFRIGERANTE
Ver la placa del número de serie.
CONTROL DE LA TEMPERATURA
Conexión 4.0°F; desconexión -10.0°F en el ajuste 1.
CONTROL DE DESCONGELACION
Se inicia un periodo 30 minutos de descongelación automática después de
cada 12 horas de funcionamiento del compresor. Durante el periodo de
descongelación un termostato apagará el calefactor de descongelación
después que se haya disuelto la escarcha del evaporador. El termostato de
descongelación se cierra a 10°F y se abre a 50°F.
RENDIMIENTO (Control en el ajuste 1)
Temperatura Ambiente
Temperatura del Compartimiento Congelador
Porcentaje de Tiempo de Funcionamiento
*Gama de Potencia (Ultimo
1
de ciclo)
3
Presión de Aspiración (Conexión, Desconexión),
2
en Lbs./pulg.
Presión Lado Alto (Ultimo
1 ⁄3
de ciclo). Lbs./pulg.
Especificaciones sujetas a cambio sin aviso previo.
*Para información completa, consultar el manual del modelo.
IMPORTANT
If any green grounding
wires are removed dur-
ing
servicing,
they
must be returned to
their original position
and properly secured.
70°F
90°F
2 to 8°F
2 to 8°F
35-45%
50-65%
115-140
120-145
14-0
14-0
100-115
140-155
PD646
IMPORTANTE
Si los alambres de puesta a
tierra verdes son sacados
durante el mantenimiento,
ellos deben volver a
colocarse en su posición
original y ser asegurados
debidamente.
70°F
90°F
2 a 8°F
2 a 8°F
35-45%
50-65%
115-140
120-145
14-0
14-0
2
100-115
140-155
SPD646
AVIS DE SÉCURITÉ IMPORTANT
L'information fournie n'est destinée
qu'au personnel de réparation qualifié.
Par suite du risque de décharge
électrique,
les
personnes
expérimentées ne devraient pas
essayer
d'entreprendre
réparations. Débrancher le cordon
avant tout entretien.
INSTALLATION
Cet appareil n'est conçu que pour être installé de façon autonome. Un
dégagement de trois pouces de chaque côté du congélateur doit être prévu
pour assurer la circulation de l'air.
Le congélateur doit être placé sur un plancher solide et l'avant de sa caisse
doit être relevé, juste assez pour permettre une fermeture facile de la porte
lorsqu'elle est à moitié ouverte.
CHARGE DE RÉFRIGÉRANT ET CARACTÉRISTIQUES ÉLECTRIQUES
Se reporter à la plaque signalétique
COMMANDE DE TEMPÉRATURE
Enclenchement 4.0°F; déclenchement -10.0°F au réglage numéro 1
COMMANDE DE DÉGIVRAGE
Une période de dégivrage de 30 minutes commence automatiquement après
12 heures de fonctionnement du compresseur. Au cours de la période de
dégivrage, un thermostat arrête l'élément chauffant de dégivrage une fois
que le givre sur l'évaporateur as fondu. Le thermostat de dégivrage se ferme
à 10°F et s'ouvre à 50°F.
PERFORMANCE (commande sur réglage numéro 1)
Température ambiante
Température du compartiment congélateur
Pourcentage de durée de fonctionnement
1
*Gamme du puissance (dernier
3
Pression d'aspiration (enclenchement,
2
déclenchement), en lb/po
au man.
Pression côté haut (dernier
1
du cycle),
3
2
en lb/po
au man.
Caractéristiques modifiables sans préavis.
*Pour des renseignements complets: se reporter au manuel du modèle.
IMPORTANT
Si des fils de mise à la
terre verts sont enlevés
lors de l'entretien, les
non
remettre à leur position
d'origine et bien les
des
fixer.
70°F
90°F
2 à 8°F
2 à 8°F
35-45%
50-65%
du cycle)
115-140
120-145
14-0
14-0
100-115
140-155
FPD646